Thetford 2117 Series Installation Manual User Manual
Page 11
![background image](/manuals/640511/11/background.png)
Installation Manual 11
Install the Baffles for an Upper Side-Wall Exhaust Vent
CAUTION:
Make sure that all horizontal baffles are the full width of
the inside of the enclosure and are in the correct location. If the
baffles are not the full width of the enclosure or incorrectly located,
poor cooling performance can result.
If the enclosure depth is 24 inches or more and less than 26 inches (See
Art01806):
- Install a wood, aluminum or galvanized steel top baffle [13] between the
top of the refrigerator and the top of the upper exhaust vent [24].
- Make sure that the top baffle is less than 1/4 inch [15] from the top of
the refrigerator and baffle overlaps the refrigerator 1 inch or less.
- Make sure that the baffle is against the wall of the vehicle at the top
of the upper exhaust vent and less than 1/4 inch above the opening
for the upper exhaust vent.
- Install an aluminum or galvanized steel bent-sheet condenser baffle
[26].
- Make sure that the bend of the condenser baffle is the full width of
the inside of the enclosure.
- Make sure that the bend of the condenser baffle is flush with the
bottom edge of the door frame of the upper side-wall exhaust vent.
- Make sure that the top edge of the condenser baffle is 1/4 inch or
less [15] from the lower rear corner of the condenser.
!
Art01806
15
13
15
15
24
26
25
9