5

owner’s manual

CAUTION

The air-in side should face up when using vacuum cleaner.

(Refer to Fig.5-4)

The air-in side should face down when using water. (Refer to

Fig.5-3)

5. Re-install the air filter

6. Install and close the air-in grill in the reverse order of step 1

and 2 and connect the control box cables to the corresponding

terminators of the main body .

Do not dry out the air filter under direct sunshine or with fire.

6. FOLLOWING SYMPTOMS ARE NOT AIR

CONDITIONER TROUBLES

Symptom 1: The system does not operate

Symptom 2: Change into the fan mode during

cooling mode

The air conditioner does not start immediately after the ON/OFF

button on the romote controller is pressed.

If the operation lamp lights, the system is in normal condition.To

prevent overloading of the compressor motor, the air

conditioner starts 3 minutes after it is turned ON.

If the operation lamp and the "PRE-DEF indicator(cooling and

heating type) or fan only indicator(cooling only type)" light, it

means you choose the heating model, When just starting, if the

compressor has not started, the indoor unit appears "anti cold

wind" protection because of its overlow outlet temperature.

In order to prevent the indoor evaporator frosting, the system

will change into fan mode automatically, restore to the cooling

mode after soon.

When the room temperature drops to the set temperature, the

compressor goes off and the indoor unit changes to fan mode;

when the temperature rises up, the compressor starts again. It

is same in the heating mode.

Symptom 3: White mist comes out of a unit

Symptom 3.1: Indoor unit

When humidity is high during cooling operation If the interior of

an indoor unit is extremely contaminated, the temperature

distribution inside a room becomes uneven. It is necessary to

clean the interior of the indoor unit. Ask your dealer for details

on cleaning the unit. This operation requires a qualified service

erson

Symptom 4.2: Indoor unit, outdoor unit

A continuous low hissing sound is heard when the system is in

operation.

This is the sound of refrigerant gas flowing through both indoor

and outdoor units.

A hissing sound which is heard at the start or immediately after

stopping operation or defrost operation.

This is the noise of refrigerant caused by flow stop or flow

change.

Symptom 4.3: Outdoor unit

When the tone of operating noise changes.

This noise is caused by the change of frequency.

Symptom 5: Dust comes out of the unit

Symptom 6: The units can give off odours

When the unit is used for the first time in a long time.

This is because dust has gotten into the unit.

The unit can absorb the smell of rooms, furniture, cigarettes,

etc., and then emit it again.

Symptom 7: The outdoor unit fan does not

spin.

During operation. The speed of the fan is controlled in order to

optimize product operation.

Sptom 4: Noise of air conditionerscooling

Symptom 3.2: Indoor unit, outdoor unit

Symptom 4.1: Indoor unit

When the system is changed over to heating operation after

defrost operation Moisture generated by defrost becomes

steam and is exhausted.

A continuous low "shah" sound is heard when the system is in

cooling operation or at a stop.

When the drain pump (optional accessories) is in operation,this

noise is heard.

A "pishi-pishi" squeaking sound is heard when the system stops

after heating operation.

Expansion and contraction of plastic parts caused by

temperature change make this noise.