Light, Applicable to fixed-frequency air conditioner only – Pridiom Concealed Duct User Manual User Manual

Page 10

background image

8

owner’s manual

Table 7-2

Solution

Clean the heat exchanger.

Clean the air filter.

Eliminate all dirties and make air

smooth.

Close doors and windows.

Make curtains in order to shelter from

sunshine.

Reduce heat source.

AC cooling capacity reduces (normal).

Check leakage and rightly recharge

refrigerant.

Symptoms

Causes

Unit does not start

Air flowing normally but

completely can't cooling

Units start or stop frequently

Low cooling effect

Low heating effect

Outdoor unit and indoor unit heat

exchanger is dirty.

The air filter is dirty.

Inlet/outlet of indoor/outdoor units is

blocked.

Doors and windows are open

Sunlight directly shine.

Too much heat resource.

Outdoor temp. is too high.

Leakage of refrigerant or lack of

refrigerant.

Use heating device.

Close doors and windows.

Check leakage and rightly recharge

refrigerant.

Outdoor temperature is lower than 7 C

Doors and windows not completely

closed.

Leakage of refrigerant or lack of

refrigerant.

Power failure.

Power switch is off.

Fuse of power switch may have burned.

Batteries of remote controller exhausted

or other problem of controller.

Temperature is not set correctly.

Be in 3 minutes protection of

compressor.

Refrigerant is too little or too much.

Air or no concretingc gas in the

refrigerating circuit.

Compressor is malfunction.

Voltage is too high or too low.

System circuit is blocked.

Wait for the comeback of power.

Switch on the power.

ReplLocation:

Replace the batterises or check the

controller.

Set the temperature properly.

Wait.

Check leakage, and rightly recharge

refrigerant.

Vacuum and recharge refrigerant.

Maintenance or change compressor.

Install manostat.

Find reasons and solution.

Table 7-1b

MALFU NC T ION & PROT EC T ION D EFINE

DISPLAY

LED 4

LED 3

LED 2

LED 1

E2

E3

E4

E6

E5

Flashing at 5HZ

Flashing at 1HZ

DIGITAL TUBE

ALARM

DEF.FAN

TIMER

OPERATION

• • •

E7

E8

Pump temperature sensor malfunction

Pipe temperature sensor checking channel

is abnormal

Water-level alarm malfunction

Room temperature sensor checking channel

is abnormal

EEPROM malfunction

Outdoor TEMP. sensor checking channel is

abnormal

Applicable to fixed-frequency air conditioner only

Light

DC motor speed out of control

Outdoor unit low pressure malfunction

Eb

Ed

Outdoor unit malfunction