Light, Applicable to fixed-frequency air conditioner only – Pridiom Concealed Duct User Manual User Manual
Page 10
8
owner’s manual
Table 7-2
Solution
Clean the heat exchanger.
Clean the air filter.
Eliminate all dirties and make air
smooth.
Close doors and windows.
Make curtains in order to shelter from
sunshine.
Reduce heat source.
AC cooling capacity reduces (normal).
Check leakage and rightly recharge
refrigerant.
Symptoms
Causes
Unit does not start
Air flowing normally but
completely can't cooling
Units start or stop frequently
Low cooling effect
Low heating effect
Outdoor unit and indoor unit heat
exchanger is dirty.
The air filter is dirty.
Inlet/outlet of indoor/outdoor units is
blocked.
Doors and windows are open
Sunlight directly shine.
Too much heat resource.
Outdoor temp. is too high.
Leakage of refrigerant or lack of
refrigerant.
Use heating device.
Close doors and windows.
Check leakage and rightly recharge
refrigerant.
Outdoor temperature is lower than 7 C
Doors and windows not completely
closed.
Leakage of refrigerant or lack of
refrigerant.
Power failure.
Power switch is off.
Fuse of power switch may have burned.
Batteries of remote controller exhausted
or other problem of controller.
Temperature is not set correctly.
Be in 3 minutes protection of
compressor.
Refrigerant is too little or too much.
Air or no concretingc gas in the
refrigerating circuit.
Compressor is malfunction.
Voltage is too high or too low.
System circuit is blocked.
Wait for the comeback of power.
Switch on the power.
ReplLocation:
Replace the batterises or check the
controller.
Set the temperature properly.
Wait.
Check leakage, and rightly recharge
refrigerant.
Vacuum and recharge refrigerant.
Maintenance or change compressor.
Install manostat.
Find reasons and solution.
Table 7-1b
MALFU NC T ION & PROT EC T ION D EFINE
DISPLAY
LED 4
LED 3
LED 2
LED 1
E2
E3
E4
E6
E5
Flashing at 5HZ
Flashing at 1HZ
DIGITAL TUBE
ALARM
DEF.FAN
TIMER
OPERATION
• • •
•
•
•
•
•
•
E7
E8
•
•
•
Pump temperature sensor malfunction
Pipe temperature sensor checking channel
is abnormal
Water-level alarm malfunction
Room temperature sensor checking channel
is abnormal
EEPROM malfunction
Outdoor TEMP. sensor checking channel is
abnormal
Applicable to fixed-frequency air conditioner only
Light
DC motor speed out of control
Outdoor unit low pressure malfunction
Eb
Ed
Outdoor unit malfunction