beautypg.com

Maintenance after a long stop period, Maintenance before a long stop period, Cleaning the air filter(on some models) – Pridiom Concealed Duct User Manual User Manual

Page 6

background image

4

owner’s manual

Maintenance after a long stop period

(eg. at the beginning of the season)

Check and remove everything that might be blocking inlet and

outlet vents of indoor units and outdoor units.

Clean air filters and casings of indoor units.

Refer to "Cleaning the air filter" for details on how to proceed

and make sure to install cleaned air filters back in the same

position.

Maintenance before a long stop period

(eg. at the end of the season)

Let the indoor units run in fan only operation for about half a day

in order to dry the interior of the units.

Clean air filters and casings of indoor units. Refer to " Cleaning

the air filter" for details on how to proceed and make sure to

install cleaned air filters back in the same position.

Check and remove everything that might be blocking inlet and

outlet vents of indoor units and outdoor units.

Clean air filters and casings of indoor units.

Refer to "Cleaning the air filter" for details on how to proceed

and make sure to install cleaned air filters back in the same

position.

Turn on the power at least 12 hours before operating the unit in

order to ensure smoother operation. As soon as he power is

turned on, the remote controller displays appear.

Cleaning the air filter(on some models)

The air filter can prevent the dust or other particulate from going

inside .In case of blockage of the filter , the working efficiency of

the air conditioner may greatly decrease .

Therefore , the filter must be cleaned once two weeks during long

time usage.

If the air conditioner is installed in a dust place , clean the the air

filter frequent.

If the accumulated dust is too heavy to be cleaned , please

replace the filter with a new one(replaceable air filter is an

optional fitting).

For your purchasing unit is a rear ventilated one, please remove

the filter fixed screws(2 screws)and take down the filter away

from the unit.

For your purchasing unit is a descensional ventilated one, please

push the filter up slightly to let the position retainer escape away

from the flange fixed holes, and take off the filter according to the

arrow direction shows in the following fig.

Fig.5-4

Fig.5-3

Clean the air filter (Vacuum cleaner or pure water may be used

to clean the air filter. If the dust accumulation is too heavy ,

please use soft brush and mild detergent to clean it and dry out

in cool place) .

Fig.5-2

Fig.5-1