Type a standard & night setback, Laboratory airflow monitors & controls, General description – Plastec Airflow Monitor A User Manual
Page 2: Led & digital

General Description
2
Laboratory Airflow Monitors & Controls
TYPE A STANDARD & NIGHT SETBACK
LED & DIGITAL
BENEFITS
• Safety: in accordance with EU laboratory
standard EN 14175
• Ease of installation and maintenance
• Fast and accurate sensor reading
• Attractive design: available in choice of LED or
digital display
RANGE
Versions:
• A LED: Monitors airflow, LED lights
• A DIGITAL: Monitors airflow, digital read out in
meter per second or feet per minute
FEATURES
• Audio and visual alarm
• 3 Pushbuttons: Fan On/Off, Light On/Off, Mute
• Alarm disabled when fan switch off
• Sash High
• Auxiliary contacts
• A 15 second or 30 second alarm delay
OPTIONS
• Surface Box Mounting: Plastic enclosure to
mount the face plate and to avoid profile cutting
the service panel.
• Alarm Relay: A remote alarm can be triggered
from a relay on the controller pcb.
• Battery Back Up: Red LED alarm is still
functional up to 12 hours when unit loses power.
• Custom Resin Stickers: Customizable resin
stickers with logo, address, etc.
COLORS
Plastic fascia is
available in:
- White (Standard)
INTERNATIONAL STANDARDS
COMPLIANCE
In accordance with:
- European laboratory standard EN 14175-2
- Electromagnetic standards EN
61326 : 1997/A1 : 1998/A2 : 2001/A3 : 2003
(Test report RC-05-42060-1) US FCC Part 15
Class B edition 2005 (Test report RC-05-
42060-2-A)
- European RoHS directive governing disposal and
recycling of electronics
- French laboratory standard XPX 15203 of Sept.
1996
- CE
COMPONENTS
• Circuit Board: Panel mounted circuit board to
be installed vertically or horizontally onto fume
cupboard with 2x Ø 2.8 mm / 0.11" screws. IP55
protection ensured by “O” ring seal. Face plate
to be supplied with chemical resistant plastic
sticker (horizontal or vertical) with control/push
buttons on fascia. Surface box mounting optional.
• Numerical and Antistatic Sensor: To be installed
inside fume hood. Sensor measures air speed
variations inside fume hood. Supplied with a
3.5 m (5 m optional) shielded cable with pin
connections onto controller circuit board.
• Power Supply: 115 VAC to 12 VDC power
transformer directly into controller circuit board.
Comes with a wall plug and cord. Adaptor may
be required to fit local power socket.
PACKING
• Supplied in cardboard box which includes con-
troller circuit board, face plate, sensor and power
transformer. Surface box mounting optional.