PD17: CP-ADAP-P47-PB (6U)
CPCI Backplane
Page 10
© 2003 PEP Modular Computers GmbH
RID 24229 PD17, Rev. 01
4.6
Auxiliary Connectors and Signals (Optional)
There are two, two-contact, male auxiliary connectors, JP16 and JP17, optionally available on
this backplane.
JP16 and JP17 make the signal lines, PRST and INH# respectively, available for external
switches to either invoke a system reset or to switch the power supply on or off.
Orientation and Pinouts of CP6-BP8-P47-STD Connectors JP16 and JP17
5.
Optional System Configurations
5.1
Power Supply Options
The design of this power distribution backplane allows for several different power supply op-
tions:
1. The default configuration of a single compatible pluggable power supply, installed either
in the upper or lower PS bay.
2. Addition of a compatible power supply installed in the upper/lower PS bay as required.
3. Addition of compatible power distribution backplanes installed either to the left or right of
the backplane as required.
Option 1 is the standard configuration which is delivered with a 47-contact female Positronic
type power supply connector.
Option 2 requires the installation of an additional compatible power supply in the appropriate
PS bay.
Option 3 requires the installation of additional power distribution backplanes as required to sup-
port the application requirements. As in option 2, compatible power supplies are required.
1
2
JP17 JP16
Table 9: Pinouts of CP6-BP8-P47-STD
Connectors JP16 and JP17
Pin
Function
JP16
1
GND
2
PRST
JP17
1
GND
2
INH#