7 standards, Standards - 12, Introduction am4100 – Kontron AM4100 User Manual
Page 30
Introduction
AM4100
Page 1 - 12
ID 36126, Rev. 2.0
P R E L I M I N A R Y
1.7
Standards
The Kontron AMC boards comply with the requirements of the following standards.
Table 1-3:
Standards
COMPLIANCE
TYPE
STANDARD
TEST LEVEL
CE
Emission
EN55022
EN61000-6-3
EN300386
--
Immission
EN55024
EN61000-6-2
EN300386
--
Electrical Safety
EN60950-1
--
Mechanical
Mechanical Dimensions IEEE 1101.10
--
Environmental and
Health Aspects
Vibration
(sinusoidal, operating)
GR-63-CORE
EN300019-2-3
IEC61131-2
IEC60068-2-6
5-150 [Hz] frequency range
1 [g] acceleration
1 [oct/min] sweep rate
10 sweeps/axis
3 directions: x,y,z
Vibration
(random, transporta-
tion)
GR-63-CORE
EN300019-2-2
IEC60068-2-64
5-20 [Hz]: 0.01[g²/Hz] ASD
20-200 [Hz]: -3 [dB] slope
8.8 [m/s² RMS] acceleration
30 [min] test time/axis
3 directions: x,y,z
Shock (operating)
EN300019-2-3
IEC61131-2
IEC60068-2-27
15 [g] acceleration
11 [ms] pulse duration
3 shocks per direction
5 [s] recovery time
6 directions, ±x, ±y, ±z
Permanent Shock
(transportation)
EN300019-2-2
IEC60068-2-29
18 [g] acceleration
6 [ms] pulse duration
100 shocks per direction
1 [s] recovery time
6 directions, ±x, ±y, ±z
Climatic Humidity
IEC60068-2-78
93% RH at 40°C, non-condensing
WEEE
Directive 2002/96/EC
Waste electrical and electronic equipment
RoHS
Directive 2002/95/EC
Restriction of the use of certain
hazardous substances in electrical and