Am5020 ipmi firmware – Kontron AM5020 IPMI Firmware User Manual
Page 29
AM5020
IPMI Firmware
ID 1045-0205, Rev. 1.0
Page 21
P R E L I M I N A R Y
17h /
A1:Board 3.3vIPM
Voltage (02h) /
Threshold (01h)
2204h / 2204h /
1212h
AMC Management Power
(MP) 3.3V
Y
18h /
A1:Board 12.0v
Voltage (02h) /
Threshold (01h)
2204h / 2204h /
1212h
AMC Payload Power (PWR)
12V
Y
19h /
A1:Board 5.0V
Voltage (02h) /
Threshold (01h)
2204h / 2204h /
1212h
Board 5V supply
Y
1Ah /
A1:Board 3.3V
Voltage (02h) /
Threshold (01h)
2204h / 2204h /
1212h
Board 3.3V supply
Y
1Bh /
A1:Pwr Good
Power supply (08h) /
OEM (77h)
0000h / 0000h /
0887h
States of all power lines
N
1Ch /
A1:Pwr Good Evt
Power supply (08h) /
OEM (77h)
0000h / 0887h /
0887h
Power fail events for all
power lines
Y
1Dh /
A1:CPU status
Processor (07h) /
Sensor-specific (6Fh)
0463h / 0400h /
04E3h
CPU thermal alarm sensor
N
1Eh /
A1:FWH0 Boot Err
Boot Error (1Eh) /
Sensor-specific (6Fh)
0008h / 0008h /
0008h
Firmware Hub 0 boot error
Y
1Fh /
A1:FWH1 Boot Err
Boot Error (1Eh) /
Sensor-specific (6Fh)
0008h / 0008h /
0008h
Firmware Hub 1 boot error
Y
20h /
A1:POST Value
OEM Post Value (C6h) /
OEM (78h)
0000h / 0000h /
00FFh
POST Value (from host I/O
port 80h)
N
21h /
A1:Lan AMC0 Link
LAN (27h) /
Sensor-specific (6Fh)
0000h / 0000h /
0003h
LAN link status –
AMC port 0
N
22h /
A1:Lan AMC1 Link
LAN (27h) /
Sensor-specific (6Fh)
0000h / 0000h /
0003h
LAN link status –
AMC port 1
N
24h /
A1:Lan Front0 Lk
LAN (27h) /
Sensor-specific (6Fh)
0000h / 0000h /
0003h
LAN link status –
Front port 0 (upper)
N
25h /
A1:Lan Front1 Lk
LAN (27h) /
Sensor-specific (6Fh)
0000h / 0000h /
0003h
LAN link status –
Front port 1 (lower)
N
Table 10: Sensor List
Sensor Number /
Name
Sensor Type (Code) /
Event/Reading Type (Code)
Ass. Mask /
Deass. Mask /
Reading Mask
Description
Health
LED Red
on Error