Hardware Sensors

Table 2-1: Hardware Sensors

2.3.2.1

IPMB-L Link Sensor

The AM4520 has an IPMB-L link to communicate with the AMC Carrier and other chassis devices on the chassis
IPMB-0 bus. MMC monitors the bus for any link failure and send the bus failure event to the AMC Carrier upon
the recovery occurs.

2.3.2.2

Module Hot Swap

The hot-swap event message conveys the current state of the module, the previous state, and a cause of the
state change as can be determined by the MMC. Refer to AMC.0 R2.0 Specifications for further details on the
module hot-swap state.

Sensor Name

Voltage/Signals Monitored

Scanning Enabled under Power State

Health LED (Green to Red)

IPMI Info-1

Internal IPMC firmware

diagnostic

Power On/Off

No change

IPMI Info-2

Internal IPMC firmware

diagnostic

Power On/Off

No change

FRU Agent

Board FRU DATA agent that verify

Data validity

Power On/Off

No change

AMC Stor Err

Management sub-system health;

non volatile memory error.

Power On/Off

No change

Board 3.3V

3.3V

Power On

Exceeds critical threshold

Board 5V

+5 V

Power On

Exceeds critical threshold

Board 12v

+12 V

Power On

Exceeds critical threshold

Board 12V Drv

+ 12V Hard Drive

Power On

Exceeds critical threshold

Board 3.3VSUS

+3.3 VSB

Power On/Off

Exceeds critical threshold

Board BlueLed

Blue LED Voltage

Power On/Off

Exceeds critical threshold

ModuleHotSwap

AMC HS State

Power On/Off

No change

IPMBL State

Operational state of IPMB-L

Power On/Off

No change

Health Error

Aggregation of healthy related

sensor

Power On/Off

Asserted/deasserted

Temp AirInlet

Board Inlet Temperature

Power On/Off

Exceeds critical threshold

Temp Exhaust

Board Outlet Temperature

Power On/Off

Exceeds critical threshold

Temp PSU In

Power Switcher In Temperature

Power On/Off

Exceeds critical threshold

Temp PSU Out

Power Switcher Out Temperature

Power On/Off

Exceeds critical threshold

MMCReboot

IPMC reboot detection

Power On/Off

No change

Ver change

IPMC firmware upgrade

detection

Power On/Off

No change