Introduction cp6002 – Kontron CP6002 User Manual
Page 40
![background image](/manuals/637835/40/background.png)
Introduction
CP6002
Page 1 - 20
ID 1036-6431, Rev. 3.0
P R E L I M I N A R Y
In addition, the CP6002-R2-MC complies with the following standards as well.
Note ...
Kontron performs comprehensive environmental testing of its products in accor-
dance with applicable standards.
Customers desiring to perform further environmental testing of Kontron prod-
ucts must contact Kontron for assistance prior to performing any such testing.
This is necessary, as it is possible that environmental testing can be destructive
when not performed in accordance with the applicable specifications.
In particular, for example, boards without conformal coating must not be
exposed to a change of temperature exceeding 1K/minute, averaged over a
period of not more than five minutes. Otherwise, condensation may cause irre-
versible damage, especially when the board is powered up again.
Kontron does not accept any responsibility for damage to products resulting
from destructive environmental testing.
Table 1-4:
Additional Standards for the CP6002-R2-MC
TYPE
ASPECT
STANDARD
REMARKS
Environmental
Random Vibra-
tion (Broadband)
ANSI / VITA 47, Class V2
Test parameters:
• 5-100 (Hz) frequency range: +3dB slope
• 100-1000 (Hz) freq. range: 0.04 (g²/Hz)
• 1000-2000 (Hz) freq. range: -6dB slope
• 7.619 g (rms)
• 60 (min) test duration/axis
• 3 axes
Single Shock
ANSI / VITA 47, Class OS1
Test parameters:
• 20 (g) acceleration
• 11 (ms) shock duration half sine
• 3 shocks per direction
• 6 directions
• 5 (s) recovery time