M2 series 2-valve brass manifold, Deep vacuum pumps – Just Better M2 Series User Manual
Page 2

Technical service: 800-323-0811
E-Mail: [email protected]
Web Site: www.jbind.com
TM
DEEP VACUUM PUMPS
Featuring
Heavy Duty,
High Performance
1/2 HP, 60 Cyc Motor
DV-42N
1.5 CFM
DV-85N
3 CFM
DV-142N 5 CFM
DV-200N 7 CFM
DV-285N 10 CFM
Also Available With
Dual Voltage Motors
1
2
4
6
7
8
9
3
5
REPAIR PARTS
See your wholesaler
for a complete line of
gauges
1 MR-503 Handwheel Screws (2)
2 MR-501B Blue Handwheel
& Screw
3 MR-516 Stem& Nut
4 MR-509 O-Ring (P90011) (2)
5 MR-505 Piston w/Seat &
O-Rings
6 MR-501R Red Handwheel
& Screw
7 M2-300 Hose Holder
8 M2-102N Hanging Hook
9 U1-4A
1/4" Intake
NO.
REF. PART NO. DESCRIPTION
NO.
REF. PART NO. DESCRIPTION
©
2006 JB Industries Inc.
LIMITED WARRANTY
INSTRUCTIONS PARTS LIST
Each gauge is individually tested and calibrated prior
to shipment. Due to its sensitivity, the gauge may
need to be "zeroed in" prior to usage.
Adjusting Gauge Recal to Zero
1. Remove lens.
2. Turn recal screw slightly in the opposite direc-
tion that pointer is to be moved. Maximum recal
screw adjustment is 1/2 turn. Over adjustment will
permanently destroy calibration.
3. Replace lens.
Turn recal screw
clockwise. Pointer turns
counter-clockwise.
Turn recal screw coun-
terclockwise. Pointer
turns clockwise.
Gauges are sensitive instruments.
Over adjustment and/or being subjected to pressures
over dial range are not covered under warranty terms.
CHARGING AND TESTING
M2 Series 2-Valve
Brass Manifold
With Free
Floating,
Double O-Ring
,
Piston Seal
,