Iw-50 film viewer for ix240 film – Canon FS 2720 U User Manual
Page 12
12
CanoScan FS2720U Film Scanner
IW-50 Film Viewer for IX240 Film
Place IX240 (Advanced Photo System) film in the IW-50 Film Viewer for insertion
into the scanner.
A
Cartridge Chamber
Place the IX240 film cartridge in here.
B
Exposure Tab
If the exposure tab, which indicates that
the film in a cartridge has been developed
when snapped down, has not been cleanly
snapped, the film will free-wheel and not
advance. Ensure that this tab is completely
snapped.
C
Cartridge Chamber Cover
Open the cover by aligning the indicator
marks
J
and pushing the open lever
G
to
the open position. Closing it with or without
a cartridge present will return the open lever
to the closed position and lock it.
D
Film Indicator
An orange mark will display when the
film is respooled and will disappear when
it is unwound. The cartridge chamber
cover
C
will not open even if the
indicator marks
J
are correctly
aligned unless the orange mark
displays in the film indicator.
E
Winder
Turn the winder counterclockwise to unwind
the film for viewing. Turn the winder
clockwise to respool the film. A mistakenly
inserted cartridge with undeveloped film will
free-wheel and not unwind.
F
Crank
The crank is useful for speeding up
unwinding and respooling.
G
Open Lever
This lever opens the cartridge
chamber cover
C
.The lever will not
operate unless the film is respooled
(orange mark displayed in the film
indicator
D
). When the chamber is
empty, the indicator marks
J
must
be aligned for the lever to operate.
H
Film Counter Window
Displays the number of the frame
appearing in the scan window
I
.
I
Scan Window
The contents of this window will be
scanned. Use the winder
E
and crank
F
to align images within this window
for scanning.
J
Indicator Marks
These marks must be aligned so that
the cartridge chamber cover
C
can be
opened with the open lever
G
.
K
Insertion Arrow
Insert a loaded IW-50 Film Viewer into
the film scanner with the insertion
arrow on top and pointing into the
scanner.
•
The insertion arrow label
K
is not applied to the film viewer when shipped.
Apply the supplied label to the label position on the film viewer before
using the unit.