beautypg.com

Below grade installations – Vermont Casting BHDT36 User Manual

Page 21

background image

- 21 -

STEP 7

Support the horizontal pipes every 36 inches (914mm)
with metal pipe straps. Make sure that the horizontal vent
pipe is installed on a level horizontal plane.

STEP 8

Recheck the fireplace to make sure that it is levelled,
properly positioned, and nailed or screwed to the floor.

If applied, the fireplaces adjustable frame drywall strips
(nailing flanges) should be fastened. See "Framing &
Finishing.

Fig. 46

DO NOT BACK FILL AROUND SNORKEL.
SOIL SHOULD NOT BE LESS THAN 4"
(100mm) BELOW SNORKEL.

BELOW GRADE INSTALLATIONS

When it is not possible to meet the required vent terminal
clearances of 12 inches (305mm) above grade level a
model 7TDVSKS vent kit is required. It allows installation
depth of down to 7 inches (178mm) below grade level. The
7 inches is measured from the centre of the horizontal vent
pipe as it penetrates through the wall.

If venting system is installed below ground,
we recommend a window well with adequate
and proper drainage.

Ensure sidewall venting clearances are observed.

The maximum horizontal run with 24" (610mm)
vertical rise is 36" (914mm) from the back of
the fireplace to the face of the exterior wall.
See vent graph (Fig. 36) for extended horizontal
run if the vertical exceeds 24" (610mm).

1.

Establish vent hole through the wall. See page 19

2.

Remove soil to a depth of approximately 16"
(406mm) below base of snorkel. Install window well
(not supplied). Refill hole with 12" (305mm) of
coarse gravel leaving a clearance of approximately
4" (100mm)below snorkel. (Fig. 47)

3.

Install vent system. See page 19/20, Steps 2
through 5.

4.

Ensure a watertight seal is made around the vent
pipe coming through the wall.

5.

Apply high temperature sealant caulking (supplied)
around the 4 and 7 inch 7TDVSKS's snorkel collars.

6.

Slide into vent pipe and secure to the wall.

7.

Level the soil so as to maintain a 4"
(100mm)clearance below snorkel (Fig. 47).

Fig. 47

,

,

,

,

,

,

,

,

,

GRAVEL

DRAIN

FIRESTOP

FOUNDATION WALL

WINDOW WELL

7DVSKS (SNORKEL)

GROUND

24"/608mm

MINIMUM*

7" PIPE

SCREWS

MINIMUM

4" CLEARANCE

ZERO CLEARANCE

SLEEVE IF REQUIRED

A minimum of 24"/608mm
vertical pipe must be installed when
using the 7DVSKS/7TDVSKS kit.

The 22" vertical rise (center to
center) of the snorkel may be
included for calculation of max.
horizontal run.

*

*