Step 1, Step 2, Step 3 – EFCO WV410 User Manual
Page 12: Step 4, Step 5, Wv410 window - installation instructions
EFCO CORPORATION 2/2014 PART NO. Y007
Page
12
of
21
WV410 WINDOW - INSTALLATION INSTRUCTIONS
Section VIII – Window Installation
A. Single Window Installation
Step 1
Locate the 1/32” inset for the WV410 frame at the horizontal mullions of the storefront D.L.O.
Step 2
The WV410 frame is mounted into the storefront opening by first drilling and countersinking
attachment holes. Drill .201” diameter (No. 7 drill) mounting holes at the WV410 frame and
countersinking for No. 10 FH-SMS SFP1 screws, 4” from the ends and 16” on center maximum.
NOTE: Be sure not to re-drill or countersink through the hinge mounting holes. See Figure 12
below.
F
F
E
.625"
Section F-F
4"
16"
16"
16"
4"
4"
16"
16"
16"
4"
Detail E
Figure #12
Step 3
Place the WV410 frame into position keeping the 1/32” offset from the interior face of the
storefront to the interior face of the WV410 frame. Place HN91 shims at the mounting screw
location and clamp the WV410 frame into place. Using the WV410 frame as a guide, drill .159”
diameter (No. 21 drill) holes into the storefront frame. Secure the vent with SFP1 screws.
Step 4
Prior to installing the window, refer to Step 8 on page 14 for the required sealing locations. If
casement vents are used, see Section VIII for lift block installation. If projected windows are
used, continue to Step 5 for vent installation.
Step 5
Reinstall the vent into the WV410 frame. Be sure to mount the hinge to the same location as
preinstalled by EFCO. See Section IX on page 20.
Note: Do not re-drill or
countersink through the hinge
mounting holes.
* Drawings on this page are not to scale.