Memory function:

After measuring, both blood pressure and pulse data will automatically be stored in the device’s memory. The memory is
able to store the last 60 measurements. When the memory is full the latest measurement data will replace the earlier ones.

The device can be programmed to calculate the mean of the last 3 measurement results.

1. The memory function of the device can be accessed after measurement or even if the device is switched off. By pressing

the upper memory knob once, the first display will show the average of the last measurements.

2. By repeatedly pressing the upper or lower memory knobs, earlier data can be displayed in chronological order. On the

bottom left side of the display, the symbol “M” and the number shows the serial number of the stored value.

To delete data from the memory, switch on the device by pressing the upper memory button once, then press again and
hold together with the “START/STOP” button until numeric values are replaced by horizontal lines on the display.

DEVICE MAINTENANCE AND CLEANING

• When not in use, store the device in its plastic box in a dry, dust- and frostfree place. Do not expose to direct sunlight, or

to extreme external temperatures.

• If you do not want to use the blood pressure meter for an extended time, remove batteries from the battery

compartment.

• Clean both the cover and cuff of the device with a moist fluff-free cloth, then wipe it thoroughly dry with a dry cloth.

• Completely dry the device before using or storing it.

• In order to obtain accurate and precise measurements, check the device yearly with your doctor.

• During cleaning, never submerge the device or its cuff into water or hold under a water tap.

• Do not dismantle the device.

• When cleaning the appliance, never use solvent (acetone, benzole, petrol, alcohol, etc.) as these may solve the casing

material, or the internal parts of the appliance if they get into. Do not use cleaning agents with coarse or grinding effect.

TROUBLESHOOTING

Failure

Possible cause

Troubleshooting

Problems detected during pumping up

Check cuff position then repeat measurement

Measurement error detected

Do not move nor speak during measurement

Low battery

Remove batteries and replace with new ones

Batteries are correctly

Batteries are not in the right position

Check polarity of batteries or replace with new ones

installed but nothing or

within the battery compartment

error is displayed when

or are flat

switched on