Longest Battery Life
Fastest Trigger Time
Page 15 of 37
use a small tweezers to access the jumper. If you lose the jumper your 
Cuddeback will still function properly with the sensitivity set to standard. If you 
are getting false detections lower the sensitivity using the jumper or software 
menu. 
 
The built in strobe flash has an effective range of about 30 feet. To assure night 
images are properly exposed we recommend aiming Cuddeback at a tree 30 to 
40 feet away. This will limit Cuddeback’s detection zone to the range of the 
camera flash and camera lens. Best images will be taken when the animal is 10 
to 15 feet from the Cuddeback. 
 
 
INSTALLING CUDDEBACK IN THE FIELD 
 
We recommend mounting Cuddeback to the largest tree in the area, about 10 
feet from where you expect the animal to appear. Place Cuddeback about 3 to 4 
feet off the ground, aiming slightly down. You can use Cuddeback’s Test 
Mode to verify the detection distance. 
 
We strongly recommend using the supplied Torx
®
screw to secure Cuddeback to
a tree. You will need a #25 Torx screwdriver. This assures solid mounting and 
you will never have to worry about a bear, deer, or vandal knocking Cuddeback 
off the tree. In addition, the supplied security cable can also be used. We also 
recommend using a padlock to secure the battery cover – even if you are on 
private property. This will assure that nobody tampers with your Cuddeback 
Digital Camera. 
 
!
WE STRONGLY RECOMMEND THAT YOU
ONLY USE THE TORX SCREW SUPPLIED.
!
 
Using a Torx screw eliminates the possibility of stripping the head. A Phillips 
head or slotted head screw is very likely to strip and prevent you from removing 
Cuddeback from the tree. 
 
Note: if you do not use the security cable you should still attach the 
supplied eye-bolt and wing nut to prevent insects from entering 
Cuddeback. 
 
Note: if you do not use the Torx screw, install the supplied Phillips-head 
screw to prevent insects from entering Cuddeback. 
 
 
FIELD CHECKING CUDDEBACK 
 
Longest Battery Life
Fastest Trigger Time
Page 16 of 37
There are two methods you can use to field check your Cuddeback camera. 
Using the a-switch method as described next, or you can follow this method. 
 
1) To check Cuddeback remove the padlock (if installed), loosen the thumb 
screw, and remove the battery cover.
2) Press (C KEY) to suspend Live Camera mode. The owner name (default
is Non Typical, Inc) will scroll across the LCD. You can skip this by 
pressing the (C KEY). (This text can be changed, refer to the TheftStop 
section in the Advanced Mode instructions). 
3) If you programmed a lock password, you will be required to enter it to
access the menu systems. If you fail to enter the correct password, 
Cuddeback will stop operating. 
4) You should press the (M KEY) to determine if any images are saved. 
5) If you have images taken, you can either 1) exchange the memory card to 
view your images at home, or 2) attach a portable TV or camcorder to view 
images. 
6) We also recommend checking the battery level and free memory space (you
must be using Advanced Mode to do this).
7) You may want to archive the images to save time viewing images the next
time you check Cuddeback (in Advanced Mode only).
8) When you are finished you can 1) attach the battery cover and leave the
area; Cuddeback will automatically enter Live Camera mode within ten 
minutes, or 2) activate Live Camera mode, replace the battery cover, and 
leave the area. 
9) If you want to move Cuddeback to a new location, we recommend
disarming Cuddeback to prevent erroneous images from being taken during 
storage and movement. 
 
THE A-SWITCH 
Cuddeback’s a-switch (short for air-switch) allows you to determine how may 
images Cuddeback has taken without opening the enclosure. 
 
How to Activate the A-Switch 
The ambient light level is the small center hole on the Cuddeback enclosure. It 
is surrounded by a small ring that allows you to recognize it by feel. To use the 
a-switch follow these steps: 
 
1) Place your finger tightly over the a-switch opening for at least 9 seconds. 
Observe the LED indicator as you do this.
2) The LED will illuminate for 1 second after the light is blocked for 9
seconds.
3) When the LED goes OFF immediately remove your finger. You must
remove your finger within ½ second of the light going off for the a-switch 
to be recognized. 