ELECTRICAL CONNECTIONS

FLASH PATTERNS

YELLOW: Alternating / Simultaneous selection.

The BLUE wires of all HIDE-A-LED™ heads must be connected to-

gether for the alternating /simultaneous function to work.

Connect to either +V or GROUND (GND).

The YELLOW wire makes the head fire AT THE SAME TIME or AL-

TERNATE with the other heads in the system.

Heads with YELLOW connected to +V fire at the same time.

Heads with YELLOW connected to GND fire at the same time.

Heads with YELLOW connected to +V will ALTERNATE with heads

that have YELLOW connected to GND.

The YELLOW wire has no function in STEADY ON mode.
SPLIT COLOR: Split color heads will always alternate flash the two

colors. The YELLOW wire will select which colors flash at the same

time and which alternate.
The HIDE-A-LED™ will also synchronize with any BULL LED™

head. The wiring colors and functions are identical.

WIRING DIAGRAM

INSTALLATION OF 4 HIDE-A-LED™ USING AN ON/OFF SWITCH AS

WELL AS A MOMENTARY SWITCH TO SELECT FLASH PATTERNS

(NOT SUPPLIED)

POWER-UP RESET:
After installing the system it is best to do a POWER-UP RESET the

first time to ensure that all heads are in sync.

Touch

BLUE wire to +V while applying power for 1 second.

Release

BLUE wire. All heads will reset to Pattern #2.

If you have installed a pattern select pushbutton, press and hold pat-

tern select while turning power switch ON. Release pattern select after

1 second. To select a flash pattern, touch

BLUE to +V or press pattern

select switch to increment the flash pattern. The heads will remember

the selected pattern even if power is removed.

ST

ANDARD + CYCLE

ST

ANDARD ONL

Y

TROUBLESHOOTING

HEAD NOT FLASHING:

Check the RED and BLACK wires for a reversed connection. (Reverse connection will

not damage the unit). Check RED and BLACK wires for either a bad splice or a corroded

ground connection.

HEADS NOT SYNCHRONIZING:

Check for a short circuit on the BLUE wire to either +V or GROUND.

Saltwater on the wire connections will short circuit the sync signal on the BLUE wire. Check

for non-functional heads in the system. If any one of the heads has a bad GROUND con-

nection it can cause the sync signal to become corrupted. If any one of the heads has it’s

RED and BLACK wires reverse connected it will corrupt the sync signal.

FLASH PATTERN CHANGING:

If the flash pattern changes on it’s own there may be an intermittent short between the

BLUE wire and +V. Check for water in the wiring connections. If any one of the heads in

the system has an intermittent GROUND connection it can also cause the flash pattern to

change.

PAGE 2

920-9078-00 REV. B

© 2009

F

F

O/

N

O

A

E

DI

S

FUSE

PATTERN

SELECT

D

E

R

K

C

AL

B

E

UL

B

W

OL

L

E

Y

YELLOW

TO +V

D

E

R

K

C

AL

B

E

UL

B

W

OL

L

E

Y

YELLOW

TO - GND

CHASSIS

GROUND

RED

D

E

R

F

F

O/

N

O

B

E

DI

S

RED

YELLOW

BLUE

D

E

R

K

C

AL

B

E

UL

B

W

OL

L

E

Y

D

E

R

K

C

AL

B

E

UL

B

W

OL

L

E

Y

STANDARD PATTERNS

#

Pattern:

Frequency: Description:

1

Quad Flash

1.25 Hz

75 Quad Flashes Per Minute

2

Double Flash

1.25 Hz

75 Double Flashes Per Minute

3

Triple Flash

1.53 Hz

92.3 Triple Flashes Per Minute

4

DeciBlast

1.42 Hz

85.5 Deci Flashes Per Minute

5

Single Flash

1.25 Hz

75 Single Flashes Per Minute

6

Mega Flash

1.90 Hz

114 Single Flashes Per Minute

7

Triple+Burst

1.37 Hz

82.5 Triple+Burst Flashes Per Minute

8

Steady On

Steady on.

Split Color = Fast Mega

CYCLE PATTERNS

9

Cycle All

Cycle through patterns 1 to 7

10

Double-Triple+Burst

2 Double, 2 Triple+Burst cycle

11

Cycle Classic

1 Double, 1 Quad, 2 Mega cycle

12

Quad-Mega

3 Quad, 4 Mega cycle

13

Single-Quad

2 Single, 2 Quad cycle

14

DeciBlast-Quad

2 DeciBlast, 2 Quad cycle

15

Single-Triple-DeciBlast

2 Single, 2 Triple, 2 DeciBlast cycle

16

Mega-Triple+Burst

1 Mega, 1 Triple+Burst cycle

STANDARD PATTERNS:

The HIDE-A-LED™ ships with only the standard patterns enabled (1

through 8). To enable cycle flash patterns follow the procedure below.
CYCLE PATTERNS:

You may add patterns 9 through 16 by following this procedure:

1) Touch BLUE wires to +V (RED wire) while applying power.

If you have installed a pattern select push-button, press and hold pat-

tern select while turning power switch ON.
2) Hold BLUE wires on +V for 5 SECONDS (heads will not be flashing

during this time). After 5 SECONDS the heads will flash once or twice

to indicate the flash pattern list that has been selected:

ONE FLASH = Standard Patterns only.

TWO FLASHES = Standard + Cycle patterns.
3) Remove the BLUE wires from +V (or release push-button).
You may switch the pattern set at any time as many times as you wish.

All heads will remember the pattern set that was selected even when

power is removed.