Electrical connections flash patterns, Wiring diagram, Troubleshooting – Code 3 Single Head Wildcat User Manual
Page 2: Pattern select
![background image](/manuals/635346/2/background.png)
ELECTRICAL CONNECTIONS
FLASH PATTERNS
YELLOW: Alternating / Simultaneous selection.
The BLUE wires of all HIDE-A-LED™ heads must be connected to-
gether for the alternating /simultaneous function to work.
Connect to either +V or GROUND (GND).
The YELLOW wire makes the head fire AT THE SAME TIME or AL-
TERNATE with the other heads in the system.
Heads with YELLOW connected to +V fire at the same time.
Heads with YELLOW connected to GND fire at the same time.
Heads with YELLOW connected to +V will ALTERNATE with heads
that have YELLOW connected to GND.
The YELLOW wire has no function in STEADY ON mode.
SPLIT COLOR: Split color heads will always alternate flash the two
colors. The YELLOW wire will select which colors flash at the same
time and which alternate.
The HIDE-A-LED™ will also synchronize with any BULL LED™
head. The wiring colors and functions are identical.
WIRING DIAGRAM
INSTALLATION OF 4 HIDE-A-LED™ USING AN ON/OFF SWITCH AS
WELL AS A MOMENTARY SWITCH TO SELECT FLASH PATTERNS
(NOT SUPPLIED)
POWER-UP RESET:
After installing the system it is best to do a POWER-UP RESET the
first time to ensure that all heads are in sync.
Touch
BLUE wire to +V while applying power for 1 second.
Release
BLUE wire. All heads will reset to Pattern #2.
If you have installed a pattern select pushbutton, press and hold pat-
tern select while turning power switch ON. Release pattern select after
1 second. To select a flash pattern, touch
BLUE to +V or press pattern
select switch to increment the flash pattern. The heads will remember
the selected pattern even if power is removed.
ST
ANDARD + CYCLE
ST
ANDARD ONL
Y
TROUBLESHOOTING
HEAD NOT FLASHING:
Check the RED and BLACK wires for a reversed connection. (Reverse connection will
not damage the unit). Check RED and BLACK wires for either a bad splice or a corroded
ground connection.
HEADS NOT SYNCHRONIZING:
Check for a short circuit on the BLUE wire to either +V or GROUND.
Saltwater on the wire connections will short circuit the sync signal on the BLUE wire. Check
for non-functional heads in the system. If any one of the heads has a bad GROUND con-
nection it can cause the sync signal to become corrupted. If any one of the heads has it’s
RED and BLACK wires reverse connected it will corrupt the sync signal.
FLASH PATTERN CHANGING:
If the flash pattern changes on it’s own there may be an intermittent short between the
BLUE wire and +V. Check for water in the wiring connections. If any one of the heads in
the system has an intermittent GROUND connection it can also cause the flash pattern to
change.
PAGE 2
920-9078-00 REV. B
© 2009
F
F
O/
N
O
A
E
DI
S
FUSE
PATTERN
SELECT
D
E
R
K
C
AL
B
E
UL
B
W
OL
L
E
Y
YELLOW
TO +V
D
E
R
K
C
AL
B
E
UL
B
W
OL
L
E
Y
YELLOW
TO - GND
CHASSIS
GROUND
RED
D
E
R
F
F
O/
N
O
B
E
DI
S
RED
YELLOW
BLUE
D
E
R
K
C
AL
B
E
UL
B
W
OL
L
E
Y
D
E
R
K
C
AL
B
E
UL
B
W
OL
L
E
Y
STANDARD PATTERNS
#
Pattern:
Frequency: Description:
1
Quad Flash
1.25 Hz
75 Quad Flashes Per Minute
2
Double Flash
1.25 Hz
75 Double Flashes Per Minute
3
Triple Flash
1.53 Hz
92.3 Triple Flashes Per Minute
4
DeciBlast
1.42 Hz
85.5 Deci Flashes Per Minute
5
Single Flash
1.25 Hz
75 Single Flashes Per Minute
6
Mega Flash
1.90 Hz
114 Single Flashes Per Minute
7
Triple+Burst
1.37 Hz
82.5 Triple+Burst Flashes Per Minute
8
Steady On
Steady on.
Split Color = Fast Mega
CYCLE PATTERNS
9
Cycle All
Cycle through patterns 1 to 7
10
Double-Triple+Burst
2 Double, 2 Triple+Burst cycle
11
Cycle Classic
1 Double, 1 Quad, 2 Mega cycle
12
Quad-Mega
3 Quad, 4 Mega cycle
13
Single-Quad
2 Single, 2 Quad cycle
14
DeciBlast-Quad
2 DeciBlast, 2 Quad cycle
15
Single-Triple-DeciBlast
2 Single, 2 Triple, 2 DeciBlast cycle
16
Mega-Triple+Burst
1 Mega, 1 Triple+Burst cycle
STANDARD PATTERNS:
The HIDE-A-LED™ ships with only the standard patterns enabled (1
through 8). To enable cycle flash patterns follow the procedure below.
CYCLE PATTERNS:
You may add patterns 9 through 16 by following this procedure:
1) Touch BLUE wires to +V (RED wire) while applying power.
If you have installed a pattern select push-button, press and hold pat-
tern select while turning power switch ON.
2) Hold BLUE wires on +V for 5 SECONDS (heads will not be flashing
during this time). After 5 SECONDS the heads will flash once or twice
to indicate the flash pattern list that has been selected:
ONE FLASH = Standard Patterns only.
TWO FLASHES = Standard + Cycle patterns.
3) Remove the BLUE wires from +V (or release push-button).
You may switch the pattern set at any time as many times as you wish.
All heads will remember the pattern set that was selected even when
power is removed.