Flash Control Switching Options

To select any one of eight different FLASH MODES , simply connect the White, Orange, Yellow and Brown
wires to a switch , or switches , in the combinations indicated in Table 1. NOTE: THE BROWN WIRE WILL
PUT THE PSE460 IN

Cycle Flash

TM

MODE WHEN CONNECTED TO (+ Vdc). THIS WILL OVERRIDE ANY

OTHER FLASH MODE SELECTED.

In the following table a “1“ = 12/24 Vdc and a “0 “ = Ground ( Earth ) or no connection.

BROWN

YELLOW

ORANGE

WHITE

FLASH MODE

0

0

0

0

ALL HEADS OFF

0

0

0

1

QUAD FLASH HEADS 1 AND 4

0

0

1

0

QUAD FLASH HEADS 2 AND 3

0

0

1

1

QUAD FLASH ALL HEADS

0

1

0

0

FIVE FLASH ALL HEADS

0

1

0

1

STANDARD DOUBLE FLASH ALL HEADS

0

1

1

0

FAST DOUBLE FLASH ALL HEADS

0

1

1

1

TRIPLE FLASH ALL HEADS

1

X

X

X

IN

Cycle Flash

TM

ALL HEADS

TABLE 1 - FLASH MODE SELECTION

Switching Control Variations

The Model PSE460 strobe outlet flashing sequence variations are controlled by four factors:

1. Selecting one or more of the Flash Modes available, see Table 1.
2. Determining the user supplied switching necessary to control these modes.
3. Choosing to connect the remote strobe light head assemblies to the alternating or simultaneous
strobe light flashing functions on the power supply outlets. See Figure 6, page 8.
4. Number of remote strobe light head assemblies used in the system.