beautypg.com

Code 3 NightProbe Controller Cable User Manual

Nightprobe, Operation, Wiring

background image

NIGHTPROBE

TM

Spotlight Control Module

for RLS, Model 3999 Siren System

DESCRIPTION:

The RLS Spotlight Control Module allows use of the RLS 3999 Siren Control to provide full control of the
NIGHTPROBE

TM

spotlight with linear acceleration from stop to full

speed.

OPERATION:

The RLS Spotlight Control Module is controlled by RLS 3999 control
unit, using the SPOT mode and the special function keys. Using the
control unit’s SELECT switch select the SPOT mode. In this mode,
depressing and holding the LEFT, RIGHT, UP or DOWN keys will
cause the NIGHTPROBE

TM

to rotate in the appropriate direction. The

spotlight will accelerate from it’s slowest speed to full speed over a two
second period and stop instantly when the switch is released. This
allows for very precise positioning of the light. Depressing and releas-
ing the center switch while in the SPOT mode will cause the lamp to toggle ON and OFF.

WIRING:

Connect the spotlight to +12VDC and Ground as described in the NIGHTPROBE

TM

User Manual. Remove the

cover from the RLS Spotlight Control Module and plug the NIGHTPROBE

TM

control cable into the 7-pin polar-

ized header on the circuit board. Replace the cover and mount the RLS Spotlight Control Module near your
RLS siren amplifier.

The control signal originates in the RLS Control Unit and is connected to the RLS system components via a
standard six conductor modular cable. Plug this modular cable into one of the modular jacks on the Spotlight
Control Module. Plug one end of the special twelve inch modular cable (p/n 10937*) provided with the Spot-
light Control Module into the remaining modular jack and plug the other end of this cable into the modular jack
on the RLS siren amplifier or the optional RLS Auxiliary Relay Module.

Please note that modular cable p/n 10937 is a special cable intended for use in interconnecting the
RLS Spotlight Control Module, RLS Auxiliary Relay Module with the RLS Siren Amplifier. DO NOT use
a standard telephone cable in place of p/n 10937. Please refer to the RLS Siren and NIGHTPROBE

TM

Remote Controlled Spotlight, User Manual for detailed instructions and further cautionary information
on the installation and wiring of the RLS Siren and NIGHTPROBE

TM

Spotlight systems.

p/n 10937

Polarized Connector

Detail

NIGHTPROBE

TM

Control Cable