The LC-LED modules are equipped with one steady burn and three flashing patterns. To select a different flash pattern, apply +12 or
+24 VDC to the red wire and connect the black wire to the power supply ground. The unit will flash in whatever pattern was last set.
Change the pattern by momentarily touching the white wire to the power supply ground. The flash pattern will change to the next
pattern according to the following list:

-Steady Burn
-75 FPM Single
-75 FPM Quad
-Cycle

Continue to cycle through the various patterns until the desired pattern is selected. The unit will retain this pattern even when power
is removed. On Dual Color Modules, placing the yellow wire to ground will cause the amber LEDs to steady burn. Placing the black
wire to ground will activate the non-amber LEDs. Most lightbars using Dual Color LCLED modules will be wired using a relay that
allows power switching to activate the non-amber portion of the unit. Note: The white flash pattern selection wire must be
protected from contact with the system ground to prevent inadvertent changes to the flash pattern. This can be accom-
plished by sealing or capping the end of the wire. Note: Regardless of the location in the program in the flash pattern list, the unit
can be forced to steady burn by permanently electrically tying the white wire to the black wire.It is recommended that all heads be set
to the desired pattern at a workbench prior to installation.

Directional module Flash Pattern - Table 2

Flash Pattern

Description

Cycle Flash

Cycles through various patterns @ 70 fpm

Steady-Burn

Steady-Burn

Five Flash

Five Pulses per flash @ 70 fpm

Quad Flash

Four Pulses per flash @ 70 fpm

Triple Flash

Three Pulses per flash @ 70 fpm

Double Flash

Two Pulses per flash @ 70 fpm

Fast Double Flash

Two Pulses per flash @ 85 fpm

NFPA

Four Pulses, 70% Duty Cycle @ 75 fpm

Quad Pop Flash

Four Pulses per flash ( 3 equal, 1 extended) @ 70 fpm

Triple Pop Flash

Three Pulses per flash ( 2 equal, 1 extended) @ 70 fpm

FIGURE 33

Flash Pattern Header for OPTIX/LEDX

J1

PCB

Momentarily short and release