CellarPro 4000SH HORIZONTAL SPLIT SYSTEM 220V 50/60HZ, 16270 User Manual
Page 14
![background image](/manuals/635124/14/background.png)
14
Power Supply Requirements
EVAPORATOR
CONDENSING UNIT
SPLIT
SYSTEM
FAN AMPS @ 115V/60HZ
POWER INPUT WATTS
UNIT AMPS @
115V/60HZ
POWER
INPUT
MODEL
MCA
HIGH
MED
LOW
HIGH
MED
LOW
MCA
LRA
WATTS
3000S/Sh
1.3
1.0
0.8
0.7
107
84
70
6.4
28.2
442
4000S/Sh
1.7
1.4
1.1
1.0
159
122
107
9.2
40.0
591
6000S
2.6
2.1
1.7
1.4
214
168
140
13.5
53.0
922
8000S
3.5
2.8
2.2
1.9
318
244
214
15.4
51.0
1028
NOTES:
SPLIT
SYSTEM
SYSTEM AMPS POWER INPUT WATTS
MODEL
MCA
LRA
HIGH
MED
LOW
3000S/Sh
7.4
28.0
549
526
512
4000S/Sh
10.6
40.0
750
713
698
6000S
15.6
53.0
1136
1090
1062
8000S
18.2
51.0
1346
1272
1242
NOTES:
Option A: Dual Power / Valve Control
Option B: Single Power / Electronic Control
1) A 15 amp dedicated circuit breaker (non GFI) is recommended for 3000S/Sh and 4000S/Sh systems.
2) A 25 amp dedicated circuit breaker (non GFI) is recommended for 6000S and 8000S systems.
1) Separate 115V / 60HZ power supplies are required for the Evaporator and the Condensing Unit.
2) A 15 amp circuit breaker is recommended for all Evaporator models.
3) A 15 amp dedicated circuit breaker (non GFI) is recommended for 3000S/Sh and 4000S/Sh Con-
densing Units
5) A 25 amp dedicated circuit breaker (non GFI) is recommended for the 8000S Condensing Unit.
4) A 20 amp dedicated circuit breaker (non GFI) is recommended for the 6000S Condensing Unit.
SINGLE 115V 60HZ POWER SUPPLY TO/FROM
EVAPORATOR