CellarPro 4000SWC SPLIT SYSTEM WATER COOLED, 7649 User Manual
Page 35
![background image](/manuals/635122/35/background.png)
35
V10.14
Remote Control / Display Instructions
Digital Display
The temperature displayed on the control is red instead of blue.
Quick Chill
Button
Button
Icon
To activate the “Quick Chill” mode, press the “Up” button for three
seconds
To deactivate “Quick Chill”, press the “Up” button for three seconds
again
The “Quick Chill” indicator (Row 3) light will turn on when the cooling unit
is in “Quick Chill” mode,
In the “Quick Chill” mode, the cooling unit will run continuously for 6 hours
(or until the unit reaches set point.). This mode is useful after loading
“warm” bottles in the cabinet.
Auto Defrost
Mode
The cooling unit has a factory default defrost cycle that initiates every
16 hours for 20 minutes. When the cooling unit is in auto-defrost mode,
the “Defrost” Indicator light (Top row) will turn on, and the evaporator
fan will run.
Manual Defrost
Hold the defrost button in for 3 seconds to initiate a manual defrost. The
“Defrost” Indicator light (Top row) will turn on for a 20 minute defrost
cycle.
Light
The light button function is disabled, however pressing it will turn on/off
the light indicator on the display (2nd row).
Energy Saver
The remote display is not configured with an Energy Saver mode. The
set point can be raised manually for periods where energy savings is
desired.