Standard Protection Mechanisms
The cooling unit is programmed to shut down certain components to protect
those components, as well as the wine inside the cellar, under the following
circumstances:
Scenario
What it means
What happens
P1 Alarm
Probe 1, which senses the
temperature inside the cellar
and controls the on/off cycles
of the cooling unit, has failed
The cooling unit enters a
timed auto-cycle mode until
Probe 1 is repaired or
replaced. In this mode, the
cooling unit will turn on for
12 minutes and off for 8
minutes.
Scenario
What it means
What happens
HA2 Alarm
P3 > 140° F
The condenser probe is
measuring temperatures that
are too hot
The compressor and
condenser fan will turn off
until the condenser
temperature falls below
120°F