CellarPro 4200VSX WINE COOLING UNIT (EXTERIOR), 1080 User Manual
Page 10
10
I I . I n s t a l l a t i o n I n s t r u c t i o n s
TEST THE UNIT BEFORE INSTALLING IT
1. Remove the unit from the box. SAVE THE BOX AND PACKING
MATERIALS.
2. Plug in the power cord and let the unit run on a hard, flat surface for no
more than 5 minutes.
3. Check to make sure that both fans (one in the front and one at the rear of
the cooling unit) are blowing.
4. Check that the cooling unit is discharging cold air from the front (it should
be approximately 10 - 12° F colder than the temperature on the digital
display)
5.
Please note
: The cooling system is programmed with a 3-Minute Delay
at Startup to protect its internal components
Cut a hole in the wall that is 1/4 inch larger than the dimensions (W x
H) of the cooling unit, and create a frame to support the rear of the
cooling unit. The rear of the cooling unit should be supported by the wall
through which it is installed. Horizontal 2 x 4 inch braces should be installed
between the studs below and above the cooling unit. If the studs in the wall
must be cut to accommodate the width of the cooling unit, vertical braces also
should be installed on either side of the cooling unit.
3200 / 4200 Frame and Cut-Out Diagram