beautypg.com

Catler ES 8013 User Manual

Page 20

background image

20

ESPRESSO PRESSURE GAUGE

IDEAL ESPRESSO ZONE

The gauge needle, when positioned in the
middle zone during extraction, indicates
the espresso will be extracted at the ideal
pressure.

UNDER EXTRACTE D ZONE

The gauge needle, when positioned in the
lower zone during extraction, indicates the
espresso has been extracted with insuffi

cient

pressure. This occurs when the water fl ow
through the ground coff ee is too fast and
results in an under extracted espresso that
is watery and lacks crema and fl avour.
Causes for under extraction include the grind
being too coarse and/or insuffi

cient coff ee

in fi lter basket and/or under tamping.

OVER EXTRACTE D ZONE

The gauge needle, when positioned in the
upper zone during extraction, indicates the
espresso has been extracted with too much
pressure. This occurs when the water fl ow
through the ground coff ee is too slow and
results in an over extracted espresso that
is very dark and bitter with a mottled and
uneven crema.
Causes for over extraction include the grind
being too fi ne and/or too much ground
coff ee in fi lter basket.

TEXTURING MILK

The Catler ES 8013 comes complete with
a commercial style 360° stainless steel steam
wand.

WARNING:
Ensure the STEAM DIAL is in the
STANDBY position before removing
the steam wand from the frothing jug.

OPERATING YOUR CATLER PRODUCT