Attention – CASO Germany VC 200 Vacuum System User Manual
Page 44
![background image](/manuals/634986/44/background.png)
caso Vakuumierer VC200
44
16.1 Safety notices
Attention
► Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment.
► Improperly performed repairs can cause considerable dangers for the user and
damages to the device.
16.2 Cause and Action
The table below helps to locate and resolve minor faults.
Error
Possible cause
Rectification
Vacuum unit is not
functioning
Power plug is not plugged in
Plug in mains plug!
Defective power cable or plug
Send device to Customer
Service
Defective electrical socket
Select another electrical
socket
The first weld on the
cut off piece of the roll
is not being carried
out.
Roll is not positioned correctly
Follow the steps in the
chapter “Vacuum packaging
in a bag originating on the
roll”
A complete vacuum is
not being created in
the bag.
The open end of the bag is not
completely inside the vacuum
chamber
Position the bag correctly
The bag is defective
Select another bag
There is dirt on the welding and
the normal seals
Clean the seals and retry
correctly once they are dry
The bag is not being
welded correctly
The welding bar is overheating so
that the bag melts
Open the cover on the unit
and let it cool down for a few
minutes
The bag does not hold
the vacuum after it has
been welded shut
The bag is defective
Select another bag; wrap
paper serviettes around any
sharp edges on the content
There are leaks along the welding
seam as a result of creases,
crumbs, grease or liquids.
Open the bag again and
clean the upper internal part
of the bag and remove any
foreign matter that might be
on the welding bar before
you weld the bag shut again.