beautypg.com

Technical service, Service hints, Specifications – Desa Tech CGD3018N User Manual

Page 27

background image

27

102986

TECHNICAL

SERVICE

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at
1-800-DESA LOG (1-800-337-2564).

SPECIFICATIONS

18" Model

24" Model

30" Model

Btu (Variable)

16,000/30,000

20,000/39,000

20,000/39,0000

Type Gas

Natural Gas Only

Natural Gas Only

Natural Gas Only

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

3.5" W.C.

3.5" W.C.

3.5" W.C.

Inlet Gas
Pressure (in. of water)

Maximum

10.5"

10.5"

10.5"

Minimum*

5"

Shipping Weight

28 lbs.

30 lbs.

32 lbs.

* For the purpose of input adjustment

When gas pressure is too low

• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat

When gas quality is bad

• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.

SERVICE

HINTS

This manual is related to the following products: