beautypg.com

Inspecting burners, Operating heater – Desa Tech CGD3018N User Manual

Page 22

background image

22

102986

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 22 shows a correct pilot flame pattern. Figure 23 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the
thermocouple to cool. When the thermocouple cools, the heater will shut down.

Thermocouple

Pilot Burner

Figure 22 - Correct Pilot

Flame Pattern

Pilot Burner

Thermocouple

Figure 23 - Incorrect Pilot

Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 23

• turn heater off (see To Turn Off Gas to Appliance, page 21)
• see Troubleshooting, pages 23 through 26

MANUAL LIGHTING PROCEDURE

1. Follow steps 1 through 5 under Lighting Instructions, pages 20 and 21.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,

release control knob. Now follow step 8 on page 21.

OPERATING

HEATER

Continued

This manual is related to the following products: