Troubleshooting – Craftsman 351.223140 User Manual
Page 7
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
Motor will not run
1. Defective plug, cord, switch or motor
1.Check wiring, replace defective parts
2. Blown fuse or circuit breaker
2. Check fuse or breaker, replace
Excessive dust in air
1. Leaking bag or hose connection
1. Check filter and collector bag connections.
Check collector hose connections
2. Filter or collector bag leaks
2. Dust trapped under bag clamp or collector bag not
sealed on collar
Excessive impeller noise
1. Large debris or piece or wood in
I.D
0
not vacuum metal materials. Turn
impeller housing
collector off and let debris settle in
collector bag.
2. Loose impeller
2. Disconnect collector from power source.
Remove four screws holding motor/fan assembly to
upper blower housing. Carefully lift out motor/fan
assembly and lay on workbench. Hold motor shaft from
turning using vise grips and tighten bolt holding impeller.
Excessive motor noise
Defective motor
Have motor checked by qualified motor
service technician
Motor fails to develop full
I.Low voltage to collector caused by
1. Remove other electric machines or
power or motor stalls
circuit overload
appliances from circuit
2. Low voltage to collector caused by
2. Increase wire gauge size of extension
undersized extension cords
cords or shorten extension cords
3
.L
0
W voltage from power source
3. Request voltage check from power
company
4. Defective motor capacitor
4
. Replace motor capacitor
Motor slow to start or fails
to reach full speed
1. Burned or defective motor
1. Check motor, replace if necessary
2. Defective motor capacitor switch
2.Check switch, replace if necessary
Motor overheats
1. Motor overload
1. Reduce lead by slowing dust production
2. Improper motor cooling
2. Clean sawdust from motor
Tripping circuit breaker or
1. Motor overloaded
1. Reduce load by slowing dust production
fuses
2. Improper capacity of circuit breaker
2. Use proper capacity circuit breaker or
or fuses
fuse