Inspect the impeller for cracks. If

cracked or damaged, do not use

the unit. Have parts replaced by

your Sears Service Center. Do not
attempt to replace them yourself.

PARTS AVAILABLE
Blower Tube...................... 530403765
Elbow Tube....................... 530403769
Upper Vacuum Tube/

Vacuum Assist Handle &

Lower Vacuum Tube . . . . 530403989
Inlet Restrictor .................. 530403791
Collection Bag .................. 530095599
Gutter Kit........................... 71-79970
Safety Glasses.................. 71-85707
Extension Cord................. 71-85709

STORAGE

a WARNING:

Perform the follow­

ing steps after each use:
• Stop unit and disconnect from the

power source.

• Allow motor to cool before storing or

transporting.

• Store unit with all guards in place.

Position unit so that any sharp object

cannot accidentally cause injury.

• Store unit unplugged, well out of the

reach of children.

SEASONAL STORAGE

Prepare unit for storage at the end of

the season or if it will not be used for

30 days or more.

If your blower is to be stored for a peri­

od of time:

• Stop unit and disconnect from the

power source.

Clean the entire unit before lengthy
storage.

Open inlet cover and clean any dirt,

grass, or debris that has collected. In­
spect the blower and all tubes. Close
and make sure the cover is latched.
Clean air vents and air inlet of debris.
Store your unit and extension cord in a

well ventilated area and covered, if

possible, to prevent dust and dirt accu­
mulation. Do not cover with plastic.
Plastic cannot breathe and may cause

condensation and eventual rust or cor­

rosion.

Check entire unit for loose screws. Re­

place any damaged, worn, or broken
parts.

TROUBLESHOOTING TABLE

A

WARNING:

Alwaysst op unit and disconnect from the power source before

performing all of the recommended remedies below except remedies that re­
quire unit to be operating.

SYMPTOWI

CAUSE

REMEDY

Unit fails to

operate.

1. Switch in the OFF position.

2. Extension cord discon­

nected.

3. Circuit breaker tripped, or

fuse blown.

4. Mechanical failure

1. Slide switch to ON position.

2. Reconnect extension cord.

3. Reset circuit breaker or

fuse.

4. Contact Sears Service

(see back cover).

Unit

vibrates

abnormally.

1. Mechanical failure

1. Contact Sears Service

(see back cover).

Impeller will

not turn

freely.

1. Debris in air intake area.

2. Mechanical failure.

1. Clean unit. Remove any

debris.

2. Contact Sears Service

(see back cover).

11