Storage – Craftsman 358.748260 User Manual
Page 11
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Inspect the impeller for cracks. If
cracked or damaged, do not use
the unit. Have parts replaced by
your Sears Service Center. Do not
attempt to replace them yourself.
PARTS AVAILABLE
Blower Tube...................... 530403765
Elbow Tube....................... 530403769
Upper Vacuum Tube/
Vacuum Assist Handle &
Lower Vacuum Tube . . . . 530403989
Inlet Restrictor .................. 530403791
Collection Bag .................. 530095599
Gutter Kit........................... 71-79970
Safety Glasses.................. 71-85707
Extension Cord................. 71-85709
STORAGE
a WARNING:
Perform the follow
ing steps after each use:
• Stop unit and disconnect from the
power source.
• Allow motor to cool before storing or
transporting.
• Store unit with all guards in place.
Position unit so that any sharp object
cannot accidentally cause injury.
• Store unit unplugged, well out of the
reach of children.
SEASONAL STORAGE
Prepare unit for storage at the end of
the season or if it will not be used for
30 days or more.
If your blower is to be stored for a peri
od of time:
• Stop unit and disconnect from the
power source.
Clean the entire unit before lengthy
storage.
Open inlet cover and clean any dirt,
grass, or debris that has collected. In
spect the blower and all tubes. Close
and make sure the cover is latched.
Clean air vents and air inlet of debris.
Store your unit and extension cord in a
well ventilated area and covered, if
possible, to prevent dust and dirt accu
mulation. Do not cover with plastic.
Plastic cannot breathe and may cause
condensation and eventual rust or cor
rosion.
Check entire unit for loose screws. Re
place any damaged, worn, or broken
parts.
TROUBLESHOOTING TABLE
A
WARNING:
Alwaysst op unit and disconnect from the power source before
performing all of the recommended remedies below except remedies that re
quire unit to be operating.
SYMPTOWI
CAUSE
REMEDY
Unit fails to
operate.
1. Switch in the OFF position.
2. Extension cord discon
nected.
3. Circuit breaker tripped, or
fuse blown.
4. Mechanical failure
1. Slide switch to ON position.
2. Reconnect extension cord.
3. Reset circuit breaker or
fuse.
4. Contact Sears Service
(see back cover).
Unit
vibrates
abnormally.
1. Mechanical failure
1. Contact Sears Service
(see back cover).
Impeller will
not turn
freely.
1. Debris in air intake area.
2. Mechanical failure.
1. Clean unit. Remove any
debris.
2. Contact Sears Service
(see back cover).
11