Before start, A drill, Flat and phillips style (star) screwdriver – LG LFC25765 User Manual
Page 25: Installation instructions, Close the main water source, Requirements, Select the location of the valve, Connecting the water line
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/631806/25/background.png)
CONNECTING THE WATER LINE
BEFORE START
The water source is not guaranteed by the refrigerator
manufacturer.
Follow
instructions
carefully
in
order
to
reduce damage.
Air located inside the water pipes can cause hammering
or tapping causing damage to the inner pipes or water
spillage in the inside of the refrigerator. Call a gualified
plumber
to
fix
such
hammering
on
the
connections
before installing the water pipe.
To avoid burn damage or such, never connect refrigerator
to hot water pipes.
If you are to use the refrigerator before connecting it
to the water source, make sure the ice maker is the off
position.
Never attempt to install the ice maker pipes in areas
where room temperature is below freezing point
When using any electrical device (like a drill) during
the installation, make sure device is doubly isolated or
making ground to prevent risk of electrical surge or
discharge.
All installations should be done considering local water
and drainage reguirements.
•
If
an
inverted
osmosis
water
filtration
system
is
connected to the cold water source, the water hose
installation
is
not
assured
or
guaranteed
by
the
refrigerator
or
automated
ice
maker
manufacturer.
Follow the next instructions carefully to minimize costly
water related damages.
•
When
having
an
inverted
osmosis
water
filtration
system connected to the cold-water flow, the water
pressure for such system must be at least between
40-60 PSI or 0,27 MPa (2,8 kg f / cm
2
~ 4,2 kg f
/ cm
2
, (2,8 kg • f / cm
2
~ 4,2 kg • f / cm
2
, less than
2 ~ 3 seconds to fill a 7 oz of capacity cup [0,2 liters]).
•
If the inverted osmosis water filtration system pressure
is less than 21 PSI or 0,14 MPa (1,5 kg • f / cm
2
, more
than four (4) seconds to fill a 7 oz of capacity cup [0,2
liters]):
a) Identify if the sediments filter in the inverted osmosis
system is being blocked. Replace filter if necessary.
b)
Allow inverted osmosis system storage tank to refill
after extensive usage.
c) Call a gualified plumber if the inverted osmosis water
pressure problem continues.
To
determine
how
much
pipe
material
is
needed,
measures
the
distances
between
the
valves
located
behind the refrigerator and the source of water and add
to that
8
feet (2,4 m). Make sure there is sufficient pipe
material to allow the free movement of the refrigerator
from the wall
• A cold water source. Water pressure should be between
0,138 and 0,82 MPa or 20 and 120 PSI for models not
containing water filter and between 0,276 and 0,82
MPa or 40 and 120 PSI for models containing water
filter.
A drill.
Adjustable 1/2" (12,7 mm) key.
Flat and Phillips style (star) screwdriver.
Two 1/4" (6,35 mm) diameter
compression
nuts
with
two
sides to connect the copper
pipe to the refrigerator valve.
If your current copper pipe has some reduction on the
ends, it will be necessary to get and
adaptor
(found
in
hardware
stores)
to connect the water line to the '
refrigerator. It is also possible to cut
such
reductions
with
a
pipe
cutter
and use the compression connections mentioned above.
• Bypass valve to connect to
the cold water line. The valve
must have a water opening ,
with
an
interior
5/32"
(3,46
mm)
diameter
in
the
cold-
water connection point. These
valves can be located in any cold-water connection
package. Before buying make sure such valve meets
local standards and reguirements.
INSTALLATION INSTRUCTIONS
Install the valve to the pipe that you use to drink water.
(Connect only to a potable water source).
0 CAUTION; Con nect to potable water supply only.
1. CLOSE THE MAIN WATER SOURCE
Open the nearest water faucet to let water flow and
empty pipes.
REQUIREMENTS
• 1/4" (6,35 mm) in diameter copper pipe to
connect refrigerator to the water pipe. Make
sure both terminals are cut in
sguared manner.
2. SELECT THE LOCATION OF THE VALVE
Select the location of the valve that will
provide a better access. It is best to
connect
to
a
vertical
pipeline.
When
connecting
to
a
horizontal
pipeline
is
necessary, make the connection in the
lateral
or
upper
area instead
of
the
lower area to prevent accumulation of
sediment
o
n
24