USB HID IntelliHead Swipe Reader


COMMANDS

Most host applications do not need to send commands to the device. Most host applications only
need to obtain card data from the device as described previously in this section. This section of
the manual can be ignored by anyone who does not need to send commands to the device.

Command requests and responses are sent to and received from the device using feature reports.
Command requests are sent to the device using the HID class specific request Set_Report. The
response to a command is retrieved from the device using the HID class specific request
Get_Report. These requests are sent over the default control pipe. When a command request is
sent, the device will Nak the Status stage of the Set_Report request until the command is
completed. This insures that, as soon as the Set_Report request is completed, the Get_Report
request can be sent to get the command response. The usage ID for the command message was
shown previously in the Usage Table.

The following table shows how the feature report is structured for command requests:

Offset Field

Name

0 Command

Number

1 Data

Length

2 – 23

Data

The following table shows how the feature report is structured for command responses.

Offset Field

Name

0 Result

Code

1 Data

Length

2 – 23

Data


COMMAND NUMBER

This one-byte field contains the value of the requested command number. The following table
lists all the existing commands.

Value

(Hes)

Command Number

Description

00

GET_PROPERTY

Gets a property from the device

01

SET_PROPERTY

Sets a property in the device

02

RESET_DEVICE

Resets the device


DATA LENGTH

This one-byte field contains the length of the valid data contained in the Data field.

DATA

This multi-byte field contains command data if any. Note that the length of this field is fixed at
22 bytes. Valid data should be placed in the field starting at offset 2. Any remaining data after
the valid data should be set to zero. This entire field must always be set even if there is no valid