Rega RP6 User Manual
Page 5

INTERCONNECTS
We have used the highest quality, purpose designed high current power connectors. The
phono plugs and interconnect cable are low noise, wide bandwidth genuine professional
products and are the best available for the job. Do not attempt to fit any other wires or
cables.
INSTALLATION
SETTING UP YOUR RB303 TONEARM
With the cartridge mounted correctly and set up using the alignment protractor
supplied, ensure that the tracking force control and bias adjustment slider are set to
zero. (Pull the bias adjustment fully out to set zero). Slide the balance weight along its
shaft until the stylus is “floating” just 1mm clear of the record.
The recommended tracking force can now be applied via the tracking force control
shown on page 5. Always use a force which corresponds to the upper limit of the
cartridge makers recommended range. Push the bias adjustment slider to the same
number as the tracking force control. ie a recommended 2.0g tracking force = 2.0 on
the bias slider. Ensure the cartridge mounting hardware is fitted correctly as shown on
page 5.
4