Dell UPS 2700R User Manual

Page 9

background image

PRO

 

Docu
 
 
 

2

3

4

 

NOTE
in con
begin 
power

 

ODUCT SUP

ument: Dell U

2. Enable SN

changes t
Reset Com

3. Edit the sh

Shutdown

4. Refer to t

points: 

a. In
b. Lo

co
sa

:  Configurations

nflict (e.g. shutdo

a shutdown imm

r remaining.

 

PORT QUIC

PS Software 

NMP through 

o take effect

mmunication.

hutdown par

n Parameters

he NMC man

nverter: refers

oad Segments
ontrolled inde
ave battery fo

i. Shutdo

remain

ii. Shutdo

iii. After x
iv. Shutdo

output

v. Restar

before

s made in this m

own 20mins afte
mediately.  This 

CK NOTES –

PSQN_SW‐A0

the Menu Â

.  To do this, c

.  Note that th

ameters that
.  Click on “Sh

nual for full in

s to the overa

s 1 & 2: refer

ependently o

or essential sy

own if remain
ning. 
own if capaci

x min: initiate

own duration

t sockets off. 

rt if capacity e

e applying pow

menu are “OR” co

er power failure,

is designed so th

– DELL UPS 

02                    

 Access Contr

click the hype

he “Reset Com

 you want to 

how advanced

formation on

all UPS contro

r to the differe

of each other 

ystems, or to 

ning time und

ty under: as a

e the shutdow

n:  time requir

exceeds: force

wer to the ou

ommands, mean

, but shutdown 
hat a server doe

MANAGEM

 

 www.DellUP

rol Â SNMP. 

erlink at the t

mmunication

take effect in

d Parameters

n the control 

ols.   

ent banks of 

(for example 

start some se

der: send shut

above, but ex

wn process aft

red for server

es the UPS to

utput sockets

ning that whiche

immediately wh

esn’t wait for 20m

MENT SOFTW

PS.com           

 You will be p

top of the pag

n” button is cl

n the event of
s” to show all

parameters, b

sockets on th

to shut down

ervers before

tdown comm

pressed as a 

ter x seconds

rs to safely sh

o wait until ba

 and allowing

ever event happe

hen battery low (

minutes to shut 

WARE 

                       

 

prompted to 
ge, or visit Me

ose to the “F

f a power fail

 shutdown se

but follows a 

he rear of the

n non essenti

e others when

and when ba

percent of ba

s on battery. 

hutdown befo

atteries achie
g servers to re

ens first will cau
(and battery IS l

down even tho

                 Ma

restart the N

enu Â System

actory Reset”

lure:  Menu Â

ettings. 

summary of 

 UPS which ca

ial systems ea

n power retur

attery has x se

attery power.

ore UPS turns

ve x% charge

estart. 

use an action.  If 

ow)), the softwa

ugh there is no b

rch, 2010

Page 9 

MC for 

m Â 

” button. 

 

key 

an be 

arly and 

rns). 

econds 

. 

 the 

e level 

timings are 

are will 

battery