Power

AC Power Supply (per power supply)

Wattage

550 W

Heat dissipation

NOTE: Heat dissipation is calculated using
the power supply wattage rating.

2132 BTU/hr maximum (redundant, 550 W power supply)

Voltage

NOTE: This system is also designed to be
connected to IT power systems with a
phase to phase voltage not exceeding 230
V.

100–240 V AC, autoranging, 50/60 Hz

Battery

Coin-cell battery

3 V CR2032 Lithium coin cell

Physical

Height

42.8 mm (1.68 inch)

Width

With rack latches

482.4 mm (18.99 inch)

Without rack latches

434.0 mm (17.08 inch)

Depth (excludes bezel)

607.0 mm (23.9 inch)

Weight (maximum)

19.9 kg (43.87 lb)

Weight (empty)

16.73 kg (36.88 lb)

Environmental

NOTE: Your system is capable of 40 °C and 45 °C excursion operation for fresh air cooled data centers. For more
information, see the

Owner's Manual

at dell.com/support/manuals.

NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.

Temperature

Maximum Temperature Gradient (Operating and
Storage)

20 °C/h (36 °F/h)

Storage Temperature Limits

–40 °C to 65 °C (–40 °F to 149 °F)

Temperature (Continuous Operation)

Temperature Ranges (for altitude less than 950 m or
3117 ft)

10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on
the equipment.

Humidity Percentage Range

10% to 80% Relative Humidity with 26 °C (78.8 °F)
maximum dew point.