Table 3. Environmental Parameters
Parameter
Specifications
Operating temperature
20 °C/h (36 °F/h)
Storage temperature
-40° to 158°F (-40° to 70°C)
Relative humidity
Storage humidity
5% to 95% RH with 33 °C (91 °F) maximum dew
point. Atmosphere must be non-condensing at all
times.
Maximum thermal output
475 BTU/hr
Maximum altitude
Operating
Storage
3048 m (10,000 ft)
12000 m (39,370 ft)
Table 4. Power Requirements
Parameter
Specifications
Power supply
90–264 VAC 50/60 Hz
Maximum current draw per system
10A per power supply
Maximum power consumption
1920W (high Line) 900 (low line)
IEEE Standards
The aggregator complies with the following IEEE standards:
• 802.3 CSMA/CD
• 802.3u 100BaseTx
• 802.3z (1000BaseSX)
• 802.3z/ab 1000BaseT
• 802.3ap 10GBase-KR
• 802.3x flow control