Page 5: Electrical, Physical characteristics

Screen dimensions
20.1 inches (20.1-inch viewable image size)
Preset display area:
Horizontal
408 mm (16.1 inches)
Vertical
306 mm (12.1 inches)
Pixel pitch
0.255 mm
Viewing angle
+/- 89° (vertical) typ, +/- 89° (horizontal) typ
Luminance output
300 cd/m ²(typ)
Contrast ratio
800:1 (typ)
Faceplate coating
Antiglare with hard-coating 3H
Backlight
CCFL (6) edgelight system
Response Time
16ms typical
Resolution
Horizontal scan range
30 kHz to 81 kHz (automatic)
Vertical scan range
56 Hz to 76 Hz, exception 1600 x 1200 at 60 Hz only
Optimal preset resolution
1600 x 1200 at 60 Hz
Highest preset resolution
1600 x 1200 at 60 Hz
Video Supported Modes
Video display capabilities (DVI playback)
480p/576p/720p
Video display capabilities (Composite playback)
NTSC/PAL
Video display capabilities (S-Video playback)
NTSC/PAL
Preset Display Modes
Dell™ guarantees image size and centering for all preset modes listed in the following table.
Display Mode
Horizontal Frequency
(kHz)
Vertical Frequency (Hz)
Pixel Clock (MHz)
Sync Polarity
(Horizontal/Vertical)
VGA, 720 x 400
31.5
70.1
28.3
-/+
VGA, 640 x 480
31.5
59.9
25.2
-/-
VESA, 640 x 480
37.5
75.0
31.5
-/-
VESA, 800 x 600
37.9
60.3
40.0
+/+
VESA, 800 x 600
46.9
75.0
49.5
+/+
VESA, 1024 x 768
48.4
60.0
65.0
-/-
VESA, 1024 x 768
60.0
75.0
78.8
+/+
VESA, 1152 x 864
67.5
75.0
108.0
+/+
VESA, 1280 x 1024
64.0
60.0
108.0
+/+
VESA, 1280 x 1024
80.0
75.0
135.0
+/+
VESA, 1600 x 1200
75.0
60.0
162.0
+/+
Electrical
Video input signals
Analog RGB, 0.7 Volts +/-5%, 75 ohm input impedance
Digital DVI-D TMDS, 600mV for each differential line, 50 ohm input
impedance
S-video, Y input 1 volt(p-p), C input 0.286 volt(p-p), 75 ohm input
impedance
Composite, 1 volt(p-p), 75 ohm input impedance
Synchronization input signals
separate horizontal and vertical,
3.3V CMOS or 5V TTL level, positive or negative sync.
SOG (Sync on green)
AC input voltage / frequency / current
100 to 240 VAC / 50 or 60 Hz + 3 Hz / 2.0A (Max.)
Inrush current
120V: 40A (Max.)
240V: 80A (Max.)