beautypg.com

Dell PowerEdge C410x User Manual

Page 16

background image

16

1. Power off GPGPU cards by ipmiutil command.

#

Type “ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 00

01”

2. Power on GPGPU cards by ipmiutil command, type the same command again will switch

current status.

#

Type “ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 00

01”

3. Reboot the HOST by ipmitool command.

#./ipmitool -I lanplus -H”HOST IP address” -U”root” -P”root” chassis power reset.

4. The “code 43” error will disappear after HOST reboot.

Example3. If GPGPU slot16 get “code 43” error

GPGPU SLOT 16 to switch on/off

1. Power off GPGPU cards by ipmiutil command.

#

Type “ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 00

80”

2. Power on GPGPU cards by ipmiutil command, type the same command again to switch current

status.

#

Type “ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 00

80”

3. Reboot the HOST by ipmitool command or other method of Remote control.

#./ipmitool -I lanplus -H”HOST IP address” -U”root” -P”root” chassis power reset.

4. The “code 43” error disappears after HOST reboot