Dell PowerEdge C410x User Manual
Page 15
15
Power GPGPU Slots On/Off To Clear Device Error "code 43"
The following table lists the IPMIUTIL raw command to switch on/off each GPGPU.
Port Map Configure Command
NetFn
CMD
Slot power control OEM command
c0h
F0h
Slot power control OEM command Byte
Data Field
Request Data
1
Bit7 : Slot 8
Bit6 : Slot 7
Bit5 : Slot 6
Bit4 : Slot 5
Bit3 : Slot 4
Bit2 : Slot 3
Bit1 : Slot 2
Bit0 : Slot 1
2
Bit7 : Slot 16
Bit6 : Slot 15
Bit5 : Slot 14
Bit4 : Slot 13
Bit3 : Slot 12
Bit2 : Slot 11
Bit1 : Slot 10
Bit0 : Slot 9
Response Data
1
Completion code
Example1. If GPGPU slot1 get “code 43” error
GPGPU SLOT 01 to switch on/off
1. Power off GPGPU cards by ipmiutil command.
#
Type “ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0
01
00”
2. Power on GPGPU cards by ipmiutil command ,type the same command again will switch
current status.
#
Type “ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0
01
00”
3. Reboot the HOST by ipmitool command or other method of Remote control.
#./ipmitool -I lanplus -H”HOST IP address” -U”root” -P”root” chassis power reset.
4. The “code 43” error will be disappeared after HOST reboot.
Example2. If GPGPU slot9 get “code 43” error
GPGPU SLOT 09 to switch on/off