beautypg.com

Dell PowerEdge C410x User Manual

Page 15

background image

15

Power GPGPU Slots On/Off To Clear Device Error "code 43"

The following table lists the IPMIUTIL raw command to switch on/off each GPGPU.

Port Map Configure Command

NetFn

CMD

Slot power control OEM command

c0h

F0h

Slot power control OEM command Byte

Data Field

Request Data

1

Bit7 : Slot 8

Bit6 : Slot 7

Bit5 : Slot 6

Bit4 : Slot 5

Bit3 : Slot 4

Bit2 : Slot 3

Bit1 : Slot 2

Bit0 : Slot 1

2

Bit7 : Slot 16

Bit6 : Slot 15

Bit5 : Slot 14

Bit4 : Slot 13

Bit3 : Slot 12

Bit2 : Slot 11

Bit1 : Slot 10

Bit0 : Slot 9

Response Data

1

Completion code

Example1. If GPGPU slot1 get “code 43” error

GPGPU SLOT 01 to switch on/off

1. Power off GPGPU cards by ipmiutil command.

#

Type “ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0

01

00”

2. Power on GPGPU cards by ipmiutil command ,type the same command again will switch

current status.

#

Type “ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0

01

00”

3. Reboot the HOST by ipmitool command or other method of Remote control.

#./ipmitool -I lanplus -H”HOST IP address” -U”root” -P”root” chassis power reset.

4. The “code 43” error will be disappeared after HOST reboot.

Example2. If GPGPU slot9 get “code 43” error

GPGPU SLOT 09 to switch on/off