beautypg.com

Dell PowerEdge Rack Enclosure 4820 User Manual

Page 3

background image

Cable Routing Procedures for Dell PowerEdge R720/R720xd Systems

3

Contents

Introduction ............................................................................................................. 4

Section 1: Cabling a PowerEdge R720/R720xd with a CMA ...................................................... 4

1.1.

Connecting the cables to the system ................................................................... 4

1.2.

Routing the power cables through the strain reliefs ................................................. 5

1.3.

Installing the CMA .......................................................................................... 5

Section 2: Replacing a power supply on a PowerEdge R720/R720xd system with a CMA ................. 8

2.1.

Replacing a power supply with a left-side mounted CMA ........................................... 8

2.2.

Replacing a power supply with a right-side mounted CMA ......................................... 8

Section 3: Cabling a PowerEdge R720/R720xd system on sliding rails without a CMA .................. 10

3.1.

Routing the cables ....................................................................................... 10

3.2.

Removing the outer CMA brackets for shallow racks .............................................. 10

Section 4: Cabling a PowerEdge R720/R720xd system installed on static rails ........................... 11

Figures

Figure 1.

System with cables installed ............................................................................. 4

Figure 2.

Routing power cables through the strain reliefs ...................................................... 5

Figure 3.

Attaching the inner CMA attachment bracket ........................................................ 5

Figure 4.

Routing the cables through the CMA .................................................................... 6

Figure 5.

Left-side mounted CMA installation (preferred) ...................................................... 7

Figure 6.

Right-side mounted CMA installation (CMA shown in service position) ........................... 8

Figure 7.

Disconnecting the CMA attachment housings ......................................................... 9

Figure 8.

Replacing the outer power supply ...................................................................... 9

Figure 9.

Cable routing without a CMA ........................................................................... 10

Figure 10.

Removing the outer CMA brackets for shallow racks .............................................. 10

Figure 11.

Cabling a system installed in static rails ............................................................. 11