4 mechanical, 4 mechanical, Table 6-7 – Cisco ONS 15200 User Manual
Page 63: Table 6-8

6-7
Cisco ONS 15200 Product Description
78-13766-01
Chapter 6 Engineering Specifications
Mechanical
Note
The operating temperature and humidity ranges are normal climatic limits, i.e., values outside these
ranges (but inside the short-term conditions specified in Telcordia GR-63-CORE) have a probability
of occurrence of less than 1 percent.
6.4 Mechanical
shows the physical dimensions of the ONS 15252 MCU subrack.
shows the physical dimensions of the ONS 15201 SCU subrack.
ONS 15252 operating humidity
range
Noncondensing (between 1 and
25 g/m
3
)
Constraint: at most 0.024 kg of
water per kg of dry air
5
85
Percent
relative
humidity
ONS 15201 operating humidity
range
Noncondensing (between 1 and
25 g/m
3
)
Constraint: at most 0.024 kg of
water per kg of dry air
5
85
Percent
relative
humidity
Table 6-6
Environmental Operating Conditions (continued)
Parameter
Condition
Min.
Max.
Unit
Table 6-7
ONS 15252 Subrack Dimensions
Parameter
Units
Height
621.8 mm (24.5 in.)
Width
485 mm (19.1 in.)
Depth
279 mm (11 in.)
Weight
37 kg (82 lb.) maximum
Table 6-8
ONS 15201 Subrack Dimensions
Parameter
Units
Height
44.5 mm (1.75 in.)
Width
480 mm (18.9 in.)
Depth
275 mm (10.8 in.)
Weight
3 kg (6.6 lb.)