2 single-channel unit optical loss, Figure 6-1, Table 6-5 – Cisco ONS 15200 User Manual
Page 60
6-4
Cisco ONS 15200 Product Description
78-13766-01
Chapter 6 Engineering Specifications
Optical
Figure 6-1
15252 MCU optical path
6.2.3.2 Single-Channel Unit Optical Loss
provides optical loss information for the SCU. See
and
to locate the
paths where loss occurs in the SCU (for example, from I to H in a Collector Filter Module [CFM]).
shows an unprotected path, and
shows a protected path in the SCU.
Insertion loss, MU-type
0.3
—
Insertion loss, SC-type
0.3
—
Table 6-4
MCU Optical Loss (continued)
Equipment
Maximum (dB)
Includes
connectors
(Y/N)
61890
LM A
NAM 1
Filterbank A
X
10% input/output
monitor A
H
P
O
V
V
HFM 1A
HFM 2A
CLIP 1
LM B
NAM 2
Filterbank B
Y
10% input/output
monitor B
I
M
N
B
K
R
HFM 2B
HFM 1B
CLIP 2
Table 6-5
SCU Optical Loss
Equipment
Maximum (dB)
Includes
connectors
(Y/N)
Collector Filter Module: Unprotected (100/0 or 0/100)
Through loss (adjacent channel), I to H
0.9
Y
Through loss (non-adjacent channel), I to H
0.8
Y
Drop loss, I to K
2.1
Y
100% Add loss, B to H
1.9
Y
Collector Filter Module: Protected (90/10 or 10/90)
Through loss (adjacent channel), I to H
1.4
Y