3 optical loss, 3 optical loss, 1 multichannel unit optical loss – Cisco ONS 15200 User Manual
Page 59: Table 6-4

6-3
Cisco ONS 15200 Product Description
78-13766-01
Chapter 6 Engineering Specifications
Optical
6.2.3 Optical Loss
This section describes the optical loss for the 15252 Multichannel Unit (MCU) and the 15201
Single-Channel Unit (SCU).
6.2.3.1 Multichannel Unit Optical Loss
provides optical loss information for the Multichannel Unit (MCU). See
to locate
the paths where loss occurs in the MCU (for example, from B to U in a Network Adaptation Module
[NAM]).
.
43
194.3
1542.94
45
194.5
1541.35
47
194.7
1539.77
49
194.9
1538.19
51
195.1
1536.61
53
195.3
1535.04
55
195.5
1533.47
57
195.7
1531.90
Table 6-3
Channel Spacing (continued)
ITU Channel
Frequency
(THz)
Wavelength
(nm)
Table 6-4
MCU Optical Loss
Equipment
Maximum (dB)
Includes
connectors
(Y/N)
Network Adaptation Module
100% (no power split)
0.3
Y
90% coupler loss, B to V or R to K
0.8
Y
50% coupler loss, B to V or R to K
3.6
Y
10% coupler loss, B to V or R to K
11.0
Y
Hub Filter Module
Through loss, (adjacent channel), M to N or O to P
0.9
Y
Through loss, (non-adjacent channel), M to N or O to P
0.8
Y
Drop loss, M to R
2.1
Y
Add loss, V to P
1.9
Y
Line Module
Through signal insertion loss, P to H, or I to M
0.8
Y
Monitor signal insertion loss, P to X, or I to Y
11.0
Y
Connectors