beautypg.com

Dell PowerEdge M600 User Manual

Information update, Running system diagnostics, System power specifications

background image

Information Update

System Board Replacement for Boards that
Support TPM – Safeguarding Encrypted Data

On blades using operating systems that support the Trusted Platform Module
(TPM) feature, you can use encryption applications to secure the contents of
the hard drive(s).

If you do use an encryption application, you are prompted to create a recovery
key during system setup. Be sure to store this recovery key. If you replace the
blade system board, you must supply the recovery key when you restart your
system before you can access the encrypted files on your hard drive(s).

Running System Diagnostics

The following note has been added to your Hardware Owner’s Manual.

NOTE:

Do not change the system configuration while running system diagnostics

on a blade because this could interfere with the test and result in false errors.

System Power Specifications

Table 1 updates the power specifications listed in your Getting Started Guide
and Product Information Guide.

Table 1.

Power Specifications

Hardware

Rating

Type B Connection PDU

200-240VAC, 30A, 3-Phase,
50/60Hz
200-240VAC, 45A, Single Phase,
50/60Hz

System - Model BMX01
(Dell PowerEdge M1000e)

200-240VAC, 30A, 50/60Hz

November 2007

YN970ap0.fm Page 9 Wednesday, November 28, 2007 2:09 PM