beautypg.com

Harbor Freight Tools Model 99792 User Manual

Page 12

background image

SKU 99792

For technical questions, please call 1-800-444-3353.

Page 12

Chipping in a Straight line:
1. Use chalk or some other suitable

writing material, mark your work

surface to delineate the area you

intend to chip.

2. Once the Hammer is attached to the

Air Compressor as described in the

instructions, place the Chisel along

one of the marked lines. Hold the

Chipping Hammer firmly with both

hands.

3. To begin chipping, depress the

Throttle Lever (6) with your thumb.

4. As the Chipping Hammer breaks

through the top layer of concrete,

press down on the Chipping Hammer

to break up the sections below the

surface as well.

5. Keep moving the Chipping Hammer

along the line you want to section,

breaking the concrete as you go.

If the Chipping Hammer jumps out

of the designated area, release the

Throttle Lever and reposition the

Chisel back inside the line.

6. Continue to chip the concrete along

the marked line until the entire area

has been sectioned.

7. When done chipping, release the

Throttle Lever and allow the tool to

stop.

Breaking up Concrete:
1. Place the Bit on the center of the

piece of concrete. Hold the Chipping

Hammer firmly with both hands.

2. Depress the Throttle Lever with

your thumb to activate the Chipping

Hammer.

3. As the chipping action begins to

break the chunks of concrete,

release the Throttle Lever to stop the

Chipping Hammer, and reposition

the Chisel on larger pieces. Do not

attempt to break up small pieces with

this tool; the chipping rate of 1800

blows per minute is too aggressive

for breaking up small pieces of

concrete.

4. If the tool requires more force to

accomplish the task, verify that the

tool receives sufficient, unobstructed

airflow (CFM) and increase the

pressure (PSI) output of the regulator

up to the maximum air pressure

rating of this tool.

CAUTION! TO PREVENT TOOL

AND ACCESSORY FAILURE,

RESULTING IN INJURY:

Do not exceed the tool’s maximum

air pressure rating.

If the tool still does not have sufficient

force at maximum pressure and

airflow, then a larger tool may be

required.

5. To prevent accidents, turn off the

tool, detach the air supply, safely

discharge any residual air pressure

in the tool. Wipe external surfaces

of the tool with clean, dry cloth, and

apply a thin coat of tool oil. Then

store the tool indoors out of children’s

reach.