2 description – Baumer PA200 User Manual
Page 14
![background image](/manuals/604915/14/background.png)
PA200
14
www.baumer.com
2 Description
2.1 System description
The process display is intended as indicator for measured values in
industrial applications.
-Voltage input ±10 V, ±20 VDC, ±200 VDC
-Voltage input ±100 mVDC for current measurement by external
resistor Shunt (measuring resistor)
-Current input ±20 mA
-Optionally linearized display
-LED display, 4 digits, programmable
-DIN housing 48 x 24 mm
2.2 Display range
Linear increase: Display scaling defines interaction of input signal and displayed
value. Linear behavior requires defining two measured values
- (inP) respectively displayed values (dSP). Both limits should be at
the end of the display area to ensure maximum precision.
Displayed
value 2
Displayed
value 1
Measured
value 1
Measured
value 2
Linear decrease: There are two options to enter the value coordinates: Either by
keypad (in SCAL mode) or using the teach-in feature (teach mode).
Assigning the displayed values requires manual entry (with device
still in teach mode). Scaling is enabled at standard signal ±10 V, ±20
mA and shunt.
Displayed
value 1
Displayed
value 2
Measured
value 1
Measured
value 2
Display
4 digits
Sticker to indicate measuring unit