Baumer MXU cameras User Manual
Page 2
LED signals
LED
Signal
Meaning
LED
green
USB 3.0 connection
yellow
USB 2.0 connection
(settings possible, no image)
Installation
Installing the camera:
Connect the camera
▪
to the USB
connection on your PC using an
appropriate cable.
If required, connect a trigger
▪
and / or flash to the digital IOs.
open wire
Data Interface / Digital IOs
USB 3.0 Micro B
1 2 3 4 5
6 7 8 9 10
1
VBUS
6
MicB_SSTX-
2
D-
7
MicB_SSTX+
3
D+
8
GND_DRAIN
4
ID
9
MicB_SSRX-
5
GND
10
MicB_SSRX+
Caution
The General Purpose IOs (GPIOs) are not potential-free and do not have
an overrun cut-off. Incorrect wiring (overvoltage, undervoltage or voltage
reversal) can lead to defects within the electronics system.
GPIO Power V
CC
:
3.3 V DC
IOUT:
max. 8 mA
The GPIOs are configured as an input through the default camera
settings. They must be connected to GPIO_GND if not used or not
configured as an output.
Digital IOs
1
8
1
Shielding
5
GPIO1
2
IN1
6
GPIO2
3
IO GND
7
IO Power VCC
4
OUT 1
8
GPIO_GND
Installation example
1 - PCI USB board
2 - USB cable
3 - Cable for trigger and flash
Troubleshooting
1. Check camera operation using the LED signals.
→ If LED is yellow:
• Camera is connected to USB 2.0 (settings possible, no image).
→ If LED is green:
• Check if camera is being used by another application.
• Otherwise reconnect camera / restart software.
2. Check connection using Windows Device Manager:
→ If device is not listed:
• Check the host controller power supply.
• Check USB 3.0 cable and connection.
→ If device is regularly not listed
• Check USB 3.0 driver installation.
Heat Transmission
Caution
Heat can damage the camera. Heat must be dissipated adequately to
ensure that the temperatures do not exceed
the values in the table below.
As there numerous options for installation, Baumer does not specify a
specific method for proper heat dissipation.
For applications with enough free space, the use of the Baumer heat sink
(No. 11118288) is recommended.
Caution
Device heats up during opera ion.
Skin irritation possible.
Do not touch the camera and/or heat sink during operation.
Measurement Point
Maximum Temperature
T
80°C (176°F)
General Description
1
2
4
5
3
No.
Description
No.
Description
1
Print sensor
4
Digital IOs
2
Flexprint cable
5
USB 3.0 port
3
System print
T