Notice, Caution – Baumer HXC cameras User Manual
Page 2
Camera Link
®
Interfaces
Notice
Baumer
Type: HXCXXx (xxxxxxx)
S/N: 000XXXXX
R1.0
CL FULL
CL BASE
CL BASE
CL FULL
The camera has two CameraLink sockets. To differentiate bet-
ween CameraLink Base and CamerLink Full socket, please look
at the label. You can not use the CL Full socket alone!
Caution
When fixing the CameraLink
®
cable with too much force the
screws might get damaged.
The maximum torque is 2.5 inch lbf [0.3 Nm].
Base Camera Link
®
Full Camera Link
®
Pin
Signal
Pin
Signal
Pin
Signal
Pin
Signal
1
GND
14 GND
1
GND
14 GND
2
X0-
15 X0+
2
Y0-
15 Y0+
3
X1-
16 X1+
3
Y1-
16 Y1+
4
X2-
17 X2+
4
Y2-
17 Y2+
5
XCLK-
18 XCLK+
5
YCLK-
18 YCLK+
6
X3-
19 X3+
6
Y3-
19 Y3+
7
SERTC+
20 SERTC-
7
100 Ω term.
20 100 Ω term.
8
SERTFG-
21 SERTFG+
8
Z0-
21 Z0+
9
CC1-
22 CC1+
9
Z1-
22 Z1+
10 CC2+
23 CC2-
10 Z2-
23 Z2+
11 CC3-
24 CC3+
11 ZCLK-
24 ZCLK+
12 CC4+
25 CC4-
12 Z3-
25 Z3+
13 GND
26 GND
13 GND
26 GND
LED Signaling
2
1
LED
Signal
Meaning
1
green
Power on
yellow
Readout active
2
green
Transmitting
red (yellow in both)
Configuration comman
processing
Power Supply / IO Pin Assignment
Caution
A power supply with electrical isolation is required for proper operati-
on of the camera. Otherwise the device may be damaged.
M8 / 3 pins
M8 / 8 pins
wire colors of the connecting cable
1
4
3
8
5
7
3
1
4
2
6
1
(brown)
Power V
CC
1
(white)
Line 9
3
(blue)
GND
2
(brown)
Line 1
4
(black)
NC
3
(green)
Line 0
4
(yellow)
GND
5
(grey)
U
ext
6
(pink)
Line 7
7
(blue)
Line 8
8
(red)
Line 2
Power Supply
Power VCC
9,6 VDC .. 30 VDC
I
200 mA .. 625 mA
Heat Transmission
Caution
Provide adequate dissipation of heat, to ensure that the temperature
does not exceed the spedified temperature.
The surface of the camera may be hot during operation and imme-
diately after use. Be careful when handling the camera and avoid
contact over a longer period.
T
T
It is very important to provide adequate dis-
sipation of heat, to ensure that the housing
temperature does not reach or exceed
+65 °C
(+149°F). As there are numerous possibilities for
installation, a specific method for proper heat dis-
sipation is not defined, but the following principles
are suggested:
Operate the cameras only in mounted
▪
condition with a good heat conductor
(e.g. aluminum)
Mounting in combination with forced
▪
convection may provide proper heat
dissipation
T: Housing temperature
measurement point
General Description
1
2
3
4
5
6
No.
Description
No.
Description
1
(respective) lens mount
4
Digital-IO supply
2
Power supply
5
CameraLink
®
Base socket
3
CameraLink
®
Full socket
6
Signaling-LED