Option programming tables – CompuSTAR CM4000 User Manual
Page 3

Option Programming Tables
Option Programming with Remotes and OP500, RPS Unlock and Secure Valet are programmable ONLY when system is Unlocked/Disarmed.
OPTION GROUP 1
Feature
Default Setting - I
Optional Setting - II
Optional Setting - III
Optional Setting - IV
1-01
Unlock before, Lock after, starting
Off
On
Lock After Remote Start
Only
Lock After Shutdown
Only
1-02
Lock / Unlock pulse duration
0.8 sec
2.5 sec
0.125 sec
3.5 sec
1-03
Driver's priority unlock
Off
On
1-04
Double pulse unlock
Off
On
1-05
Rearm Output
After Start Shutdown
and First Lock
After Start Shutdown
and Every Lock
After Start Only
After Shutdown Only
1-06
Reservation Lock
(Manual transmissions)
Locks When
Reservation Mode is Set
Does Not Lock When
Reservation is Set
Reservation Sets 10
Seconds After the Last
Door is Closed
1-07
Unlock / Disarm With Trunk Release
Unlock, Factory Disarm,
and Trunk Release
Factory Disarm, Trunk
Release Only
Trunk Release Only
1-08
Locking while in Passive Arming
Passive locking with
Passive Arming
No Passive Locking with
Passive Arming
1-09
Ignition controlled door locks
Off
On
RPM Locks (Tach
Sensing Mode Only)
1-10
Auto Relock (If a door is not opened
within this amount of time)
Off
30 sec
60 sec
5 min
1-11
Ignition / Accessory Out Upon Unlock
Off
Ignition Pulse - same
timing as disarm pulse
Acc Pulse - same timing
as disarm pulse
Ignition and Acc Pulse -
same timing as disarm
pulse
1-13
Double Pulse Disarm Input
Single Pulse
Double Pulse
1-14
Auto Lock Mode (2 Way International
Remotes)
Off On
OPTION GROUP 2
Feature
Default Setting - I
Optional Setting - II
Optional Setting - III
Optional Setting - IV
2-01
Tach Sensing Method
Optimal Tach Method
Previous Tach Method
Low Threshold Tach
Method
2-02
Turbo Timer
Off
2 Min
1Min
4 Min
2-03
Diesel Timer
Wire
3~99sec (10sec Default)
2-04
Trigger Start
Off
Single Pulse
Double Pulse
Triple Pulse
2-05
Cold Start with Thermistor Assembly
Off
On
2-06
Timer Start, or, Minimum Interval
Between Cold Starts
3 Hour (4 minute
runtime, double for
Diesel)
1.5 Hour(4 minute
runtime, double for
Diesel)
Reservation
(Runtime set by 2-7)
2 Way LCD Remotes
Only
24 Hour Repeat with
Cold Starting of 2-8
(Runtime set by 2-7) 2
Way LCD Only
2-07
Remote Start Runtime
15 Min
25 Min
45 Min
3 Min
2-08
Temperature of Cold Starting
-10° C / 14° F
-20° C / -4° F
-5° C / 23° F
-15° C / 5° F
2-09
Temperature of Hot Starting
25° C / 77° F
30° C / 86° F
35° C / 95° F
40° C / 104° F
2-10
Engine Sensing
Tach
Alternator
No Connection – No
Tach Sensing
(Not for Manual
Transmissions)
No Connection – 1.5
Second Crank
(Not for Manual
Transmissions. V.33 or
greater)
2-11
Turbo, Remote Start Runtime
Extension w/ #1 for 2 seconds
No Yes
2-12
Crank Time
Standard
+0.2 Seconds to Crank
Time
+0.6 Seconds to Crank
Time
(No Tach Sensing Only)
(-)0.2 Second Crank
Time
OPTION GROUP 3
Feature
Default Setting - I
Optional Setting - II
Optional Setting - III
Optional Setting - IV
3-01
Parking lights While Remote Started
Constant Output
Flashing Output
Off
3-02
Dome Light output
Off
Factory Rearm
45 sec
Factory Rearm + 45 Sec
3-03
Dome Light Delay
Off
5 sec
45 sec
Auto
3-04
Starter-Kill Relay
Anti-Grind + Starter Kill
Anti-Grind
Anti-Grind +
Passive Starter Kill
3-05
Anti-Jacking Starter-kill
Ignition-Kill
(no Anti-Grind)
Auto kill
(Auto-door locks Off)
International Remotes
w/ AUTO Function Only
Auto kill
(Auto-door locks On)
International Remotes
w/ AUTO Function Only
3-07
Siren Duration (Upon Alarm Trigger)
30 sec
60 sec
120 Sec
Chirps for 20 seconds
3-09
Horn Output When Alarm Is Triggered
Pulsed Output
(Horn)
Constant Output
(Secondary Siren)
3-10
Valet
Key 5 times, or Remote
(I+III) while Ignition is On
Key 5 times or Remote
(I+III)
Secure Valet
(Default code 3,3)
3-11
Auxiliary settings Mode
Disabled
Enabled
3-12
Auxiliary settings With Passive Arming
No Passive Arming
Passive Arming