Alternator - police, Power distribution connector, Crown victoria severe duty – FORD 2010 Crown Victoria v.2 User Manual
Page 272
charger designed for commercial use such as the Rotunda GR-1. Never
let a fully discharged battery remain discharged for a long period of time.
Extended storage in a discharge state can cause irrecoverable damage to
the internal components or cracking of the container. As a battery
approaches a discharged state it becomes easier for the electrolyte to
freeze. If it freezes and expands it may crack the battery case.
Alternator - police
The high-output alternator provides 200 amperes of current to support
the high power requirements of modern police equipment. Output at idle
is approximately 130 amperes. Current demand by both the vehicle and
all energized police equipment in excess of this amount during vehicle
idling will place the electrical system into a discharge condition.
Electrical power management systems should be applied if necessary to
avoid discharging the battery.
Power distribution connector
Power for aftermarket equipment can be obtained from the power
distribution connector located under the glove compartment. This
connector contains several fused power feeds and inputs available for the
addition of accessories. The following tables show the circuits available
for equipment.
Police
Pin
Function
Gauge
Color
1
5A Start
18
Red/Black
2
Vehicle speed signal
18
Gray/Black
3
Battery saver
18
Dark green/Light green
4
20A Battery
14
Light green
5
15A Battery
18
Orange/Light green
6
50A Battery
10
Tan/Yellow
7
20A Run/Acc
14
Pink
8
20A Battery
14
Light Blue/White
9
20A Run/Acc
14
Tan
10
Hazard out
18
Black/Yellow
11
50A Battery
10
Red/White
12
Hazard In
18
Gray/White
Crown Victoria Severe Duty
272
2010 Crown Victoria (cro)
Owners Guide, 2nd Printing